{"product_id":"2000361-001-tricon-sis-16-channel-digital-output-module-triconex","title":"2000361-001 Tricon SIS 16-Channel Digital Output Module | Triconex","description":"\u003cp\u003eThe Triconex \u003cstrong\u003e2000361-001\u003c\/strong\u003e is a 16-channel digital output module developed for Tricon Safety Instrumented Systems (SIS). Operating within triple modular redundant (TMR) architectures, it converts controller safety logic outputs into reliable on-site switch control signals to govern critical safety elements such as emergency shutdown valves and safety relays.\u003c\/p\u003e\n\u003ch3\u003eFunctional Architecture and Diagnostics\u003c\/h3\u003e\n\u003cp\u003eDesigned for the Tricon TMR environment, the module features 16 independent output channels to handle rigorous process control demands. Each channel incorporates active short-circuit detection and over-temperature protection mechanisms to maintain loop integrity and secure operation under hazardous conditions.\u003c\/p\u003e\n\u003ch3\u003eOperating Limits and Maintenance\u003c\/h3\u003e\n\u003cp\u003eThe unit complies with IEC 61508 SIL3 safety integrity requirements and operates within a temperature range of -20 deg C to +60 deg C, supporting a maximum load capacity of 2 A per channel at 60 deg C (adjusting to 0.5 A at 70 deg C). It weighs 2.0 kg and supports live insertion and replacement (hot-swapping) in dedicated chassis slots without requiring a full system shutdown.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2000361-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTriconex (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Channels\u003c\/td\u003e\n\u003ctd\u003e16 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle Channel Load Capacity\u003c\/td\u003e\n\u003ctd\u003e2 A at 60 deg C (0.5 A at 70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Features\u003c\/td\u003e\n\u003ctd\u003eActive short-circuit detection, over-temperature protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 SIL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eTriple Modular Redundant (TMR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Frequency Adaptation\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot-Swap Support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Method\u003c\/td\u003e\n\u003ctd\u003eDedicated slot in Tricon main or expansion chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Can the Triconex 2000361-001 module be replaced while the safety system is active?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it supports hot-swap replacement, allowing maintenance personnel to exchange units in designated slots without shutting down the entire system.\u003c\/p\u003e\n\u003cp\u003eQ: What safety classification does this digital output module hold?\u003c\/p\u003e\n\u003cp\u003eA: It is certified to meet IEC 61508 SIL3 safety integrity level requirements for high-risk safety instrumented applications.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current load rating per channel?\u003c\/p\u003e\n\u003cp\u003eA: Each channel supports a maximum load capacity of 2 A at 60 deg C, adjusting to 0.5 A at an elevated temperature of 70 deg C.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":68225115554088,"sku":"2000361-001","price":327.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/DO3201_Cocoai_c4278390-9259-4a7c-bb1b-bebec4e6cac1.png?v=1794983629","url":"https:\/\/www.powerdcs.com\/ar\/products\/2000361-001-tricon-sis-16-channel-digital-output-module-triconex","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}