51196653-200 DCS Power Supply | Honeywell

Specifications

  • Manufacturer: Honeywell

  • Product No.: 51196653-200

  • Condition: 10 العناصر الموجودة في المخزون

  • Product Type: Power Supplies

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 300g

  • Shipping port: Xiamen

  • Warranty: 12 months

تفاصيل المنتج

وصف

The Honeywell 51196653-200 (Revision Level F) is a 5-slot power supply featuring Power Factor Correction (PFC) and CE compliance. Designed as the updated power solution for 5-slot chassis architectures, it incorporates auto-ranging input voltage capabilities to accommodate fluctuating AC supply levels in industrial environments.

Power Input and Compatibility

The unit supports an auto-ranging input voltage range of 102 to 264 RMS with integrated PFC functionality. It is equipped with a standard 3-pin power connector, meaning it requires a replacement cable when installed in original 5-slot chassis units originally built with an 8-pin power connector configuration.

Clock Configuration and SOE Settings

Units are shipped pre-pinned for internal line frequency clock operation. When Sequence of Events (SOE) functionality is required on a Network Interface Module (NIM), the clock master, clock slave, and associated NIM nodes must be manually re-pinned to use external clocks using the clearly marked onboard jumper located behind the finger connector.

Technical Specifications

Parameter Specification
Model Number 51196653-200
Revision Level Revision F
Manufacturer Honeywell
Product Type DCS Power Supply (5-slot chassis)
Certifications CE-compliant
Input Voltage Range Auto-ranging 102 to 264 RMS
Power Factor Correction Included (PFC)
Power Connector Standard 3-pin connector
Clock Configuration Pinned for internal line frequency clock (field-switchable to EXT)

Frequently Asked Questions

Q: What cable modification is required when installing this power supply in older equipment?

A: Because this supply uses a standard 3-pin connector, a replacement cable is required if it is used with an original 5-slot chassis that features an 8-pin power connector.

Q: How do you configure the module for external clock use when Sequence of Events is needed?

A: You must change the onboard jumper located directly behind the finger connector from the factory default internal (INT) setting to the external (EXT) position.