51202329-512 Violet Drop / I/O Link Cable | Honeywell
Specifications
Manufacturer: Honeywell
Product No.: 51202329-512
Condition: 10 العناصر الموجودة في المخزون
Product Type: Network Cables
Product Origin: USA
Payment:T/T, Western Union
Weight: 1500g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
The Honeywell 51202329-512 (also cataloged as 51202329 Violet Drop Cable) is a structured 3-drop I/O link cable designed for signal routing in Honeywell Experion PKS (C300) and TDC 3000 control platforms. Designated as Cable A with a yellow label identification, it provides reliable channel connections for cabinet configurations containing two CF9 controllers, two C300 modules, and one 6-inch IOTA.
Channel Isolation and Signal Protection
The cable assembly incorporates channel-to-channel isolation to prevent mutual signal interference between connected I/O link hardware components. As a passive cable, it consumes no power and maintains signal integrity across controller and I/O termination interfaces.
Cable Identification and Installation
Featuring a violet outer jacket combined with a yellow identification label, the cable simplifies physical identification and drop mapping within dense wiring panels. The assembly is built to support system-level redundant controller architectures across control-room ambient operating environments.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | 51202329-512 |
| Brand | Honeywell |
| Product Type | Violet Drop / I/O Link Cable |
| Cable Identification | Yellow label (Cable A) |
| Number of Drops | 3 drops |
| Power Consumption | Passive cable (0 W) |
| Operating Temperature | Control-room ambient range |
| System Compatibility | Honeywell Experion PKS (C300), TDC 3000 |
| Application | Channels with two CF9s, two C300s, and one 6 in IOTA |
| Origin | USA |
Field Installation Guidelines
- Verify Cable A (yellow label) identification to ensure accurate drop assignment and channel mapping.
- Route violet drop cables separately from high-voltage AC lines to prevent induced electromagnetic noise.
- Terminate cable shielding at the controller ground point only to avoid ground loop currents.
- Observe minimum bend radius limits during cable installation to prevent internal conductor damage.
- Perform continuity and channel mapping verification using loop test equipment before system commissioning.
Frequently Asked Questions
Q: What specific hardware configuration is the 51202329-512 cable designed for?
A: It is designed for channels connecting two CF9 controllers, two C300 modules, and one 6-inch IOTA assembly.
Q: How is the cable identified for proper channel assignment?
A: The cable features a violet outer jacket and a yellow label designating it as Cable A.
Q: How should shielding be grounded during installation?
A: Cable shielding must be connected to earth ground at the controller end only to prevent ground loop currents.