51202329-802 | Honeywell | I/O Link Cable
Specifications
Manufacturer: Honeywell
Product No.: 51202329-802
Condition: 10 العناصر الموجودة في المخزون
Product Type: Industrial Computer Cables
Payment:T/T, Western Union
Weight: 90g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
Configured for power distribution and link protection interconnection in process automation networks, the Honeywell 51202329-802 (51202329-802 Cable Set PM Power with Link Protect REV C) provides direct physical signal transmission and power routing across control cabinet nodes.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 51202329-802 |
| Brand | Honeywell |
| Origin | United States |
| Weight | 0.09 kg (approx. 0.20 lbs) |
| Dimensions | Standard industrial cabinet length |
| Operating Temp | 0 deg C to 60 deg C |
| Power Consumption | Passive cabling component |
| Cable Type | PM Power with Link Protect (REV C) |
| Interface Compatibility | Process Manager power distribution assemblies |
Honeywell DCS Process Control and Signal Communication
The assembly integrates within Honeywell process automation architecture, maintaining strict channel-to-channel isolation and cold junction compensation (CJC) path integrity across distributed nodes. Standard configuration supports 4-20 mA HART loop protocol environments alongside power distribution layers. The physical wiring architecture ensures deterministic bus operation and low-latency power delivery between module power supplies and link protector hardware.
Frequently Asked Questions
Q: Does the 51202329-802 support hot-swapping on active controller networks?
A: Cabling adjustments must be performed with upstream loop power and power distribution buses isolated to prevent electrical arcing or transient voltage spikes on connected control nodes.
Q: Is this cable set compatible with link protection module assemblies?
A: Yes, this specific variant is engineered explicitly to connect PM power distribution systems featuring inline link protection (REV C).
Field Installation Guidelines
- Verify that system power supplies and distribution loops are de-energized prior to routing and connecting the cable set between controller nodes and power assemblies.
- Route the cable along designated internal cabinet wireways, maintaining physical separation from high-voltage AC power lines to prevent induced noise coupling.
- Secure connector plugs firmly to terminal interfaces, ensuring locking mechanisms or retention screws are fully engaged to withstand industrial vibration environments.
كيفية الحصول على عرض أسعار
تتبع الطلب
شركات الشحن
سياسة وشروط الاسترداد
شروط الضمان
منتجات ذات صله