{"product_id":"8c-taix61-51306977-175-series-8-analog-input-module-honeywell","title":"8C-TAIX61 51306977-175 Series 8 Analog Input Module | Honeywell","description":"\u003cp\u003eConfigured for high-accuracy signal digitization in Experion PKS platforms, the \u003cstrong\u003eHoneywell 8C-TAIX61 51306977-175\u003c\/strong\u003e (\u003cstrong\u003e8C-TAIX61\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX61 51306977-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 mm x 120 mm x 152.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eUnspecified (-40 to +70 deg C standard industrial class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eUnspecified (24 VDC system power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51306977-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types Supported\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current, 0-10 V voltage, Resistance inputs (RTDs, sensors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003eConfigurable (0-20 mA, 4-20 mA, 0-10 V, etc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;250 ohm (current), \u0026gt;1 Mohm (voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Isolation\u003c\/td\u003e\n\u003ctd\u003eElectrical isolation between input and system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 8C-TAIX61 51307133-175 converts incoming analog process variables into digital format using an onboard 16-bit analog-to-digital converter (ADC) sampling at response rates under 100 ms. Built-in galvanic isolation between the field input terminals and the backplane system bus suppresses high common-mode voltages and electrical noise spikes from reaching core logic circuitry. Supported current loop pathways maintain low input impedance (\u0026gt;250 ohm) and preserve bidirectional 4-20 mA HART loop protocol pass-through communication, allowing dynamic device variable access and HART diagnostic passthrough directly to Experion control networks without signal attenuation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 8C-TAIX61 support hot-swapping during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports removal and insertion under power (RIUP) when installed on a compatible Series 8 IOTA base, enabling slot maintenance without interrupting adjacent bus communication.\u003c\/p\u003e\n\u003cp\u003eQ: How is the input range configured for different sensor types on the 8C-TAIX61?\u003c\/p\u003e\n\u003cp\u003eA: Input signal ranges (4-20 mA, 0-10 V, or RTD resistance modes) are parameterised per channel via software within the Honeywell Experion PKS engineering environment.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanisms prevent electrical noise from impairing the 16-bit resolution accuracy?\u003c\/p\u003e\n\u003cp\u003eA: High input impedance (\u0026gt;1 Mohm in voltage mode) and field-to-bus electrical isolation filter out high-frequency transients and ground loop potentials.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Base Engagement\u003c\/strong\u003e: Align the module edge connector with the designated slot on the Series 8 IOTA carrier and press firmly until the mechanical locking latches fully secure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Ground Termination\u003c\/strong\u003e: Connect field signal cable drain wires directly to the designated enclosure grounding bar to prevent stray electromagnetic interference on low-level signal paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Conduit Isolation\u003c\/strong\u003e: Separate analog input signal cables from high-voltage AC power lines and variable frequency drive (VFD) motor cables in dedicated cable trays.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52312981307688,"sku":"8C-TAIX61 51306977-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/8C-TAIX61.png?v=1788256895","url":"https:\/\/www.powerdcs.com\/ar\/products\/8c-taix61-51306977-175-series-8-analog-input-module-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}