900P24-0001 Power Supply Module | Honeywell
Specifications
Manufacturer: Honeywell
Product No.: 900P24-0001
Condition: 10 العناصر الموجودة في المخزون
Product Type: Power Supply Modules
Payment:T/T, Western Union
Weight: 580g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
Configured for DC-to-DC regulated power conversion and voltage rail distribution within ControlEdge HC900 architectures, the Honeywell 900P24-0001, also cataloged as the 900P24-0001 24 VDC Regulated Power Supply Module, provides direct physical/electrical execution.
Suffix Breakdown & Model Matrix
| Model Suffix | Input Voltage Range | Output Power Rating | System Architecture Compatibility |
|---|---|---|---|
| 900P24-0001 | 24 VDC (plus-minus 10 percent) | 2.5 A continuous (3 A peak) | ControlEdge HC900 I/O racks |
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 900P24-0001 |
| Brand | Honeywell |
| Origin | Standard Industrial Manufacturing |
| Weight | 1.27 lbs |
| Dimensions | 45 mm x 125 mm x 110 mm |
| Operating Temp | -20 deg C to +70 deg C |
| Power Consumption | Up to 3 A input current |
| Input Rating | 24 VDC |
| Output Rating | 24 VDC regulated (Ripple noise less than 100 mV peak-to-peak) |
Channel-To-Channel Isolation And Loop Protocol Integrity
The power supply module incorporates galvanic isolation barriers between primary DC input terminals and secondary regulated output rails to suppress common-mode noise and high-voltage transients. It supports downstream 4-20 mA HART loop protocol power distribution requirements across connected I/O cards without introducing ground loops. Integrated internal voltage regulation circuitry, overcurrent protection with auto-reset, and cold junction compensation (CJC) reference stabilization protect system processing nodes against line voltage fluctuations and thermal drift.
Frequently Asked Questions
Q: Does the 900P24-0001 power supply module support hot-swapping during active operation?
A: Yes, the module supports hot-swapping capabilities to allow system maintenance and replacement without shutting down the entire control rack.
Q: What protection features are integrated into the power supply circuitry?
A: The unit features built-in overcurrent protection with auto-reset and an overvoltage clamp circuit to safeguard downstream electronic loads.
Field Installation Guidelines
- Verify that primary DC input power is isolated, locked out, and tagged out prior to handling or wiring the power supply module.
- Mount the unit securely in the designated rack slot of the ControlEdge system, ensuring firm mechanical engagement with backplane power pins.
- Check input terminals and output wiring connections for secure mechanical clamping and proper insulation before energizing.
- Measure operating input voltage ranges using a calibrated digital multimeter to verify correct supply parameters prior to system startup.