{"product_id":"cc-paoh01-51405039-175-honeywell-hart-analog-output-module","title":"CC-PAOH01 51405039-175 Honeywell HART Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAOH01 51405039-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-PAOH01\u003c\/strong\u003e HART Analog Output Module, operates as a dedicated hardware component for high-level analog signal generation and two-way digital field communication within Honeywell Experion PKS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAOH01 51405039-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e152 x 61 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC system power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh-level Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X, IP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe CC-PAOH01 module provides precise high-level analog driving current to field actuators while supporting two-way digital communication via the 4-20 mA HART loop protocol. Integrated high-resolution digital-to-analog conversion at 12 bits combined with a 100 Hz sampling rate ensures continuous feedback loop control for valve positioners and current-to-pressure transducers. The onboard channel circuitry maintains isolation between system logic and field wiring to block voltage spikes and line noise from impairing DCS central processing functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-PAOH01 module support simultaneous analog output driving and digital HART data transfer?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module superimposes digital HART frequency-shift keying (FSK) signals onto the standard 4-20 mA analog output current without disturbing the analog command signal.\u003c\/p\u003e\n\u003cp\u003eQ: How is the module protected against severe environmental exposure in field enclosures?\u003c\/p\u003e\n\u003cp\u003eA: The physical housing carries NEMA 4X and IP66 ratings, sealing internal electronics against dust, moisture ingress, and corrosive atmospheres across an operating temperature range of -40 to 85 deg C.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CC-PAOH01 be hot-swapped while the Experion PKS controller is online?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports online insertion and removal under system backplane power without interrupting adjacent chassis I\/O channels or controller execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the CC-PAOH01 module onto the C300 I\/O carrier rack, engaging side locking tabs to ensure solid grounding to the enclosure DIN assembly.\u003c\/li\u003e\n\u003cli\u003eConnect field loop cabling using shielded twisted-pair conductors to mitigate electromagnetic interference and maintain 4-20 mA HART signal integrity.\u003c\/li\u003e\n\u003cli\u003eGround cable shield drain wires at a single point on the main control cabinet ground bar to prevent ground loops across isolated channels.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring polarity before applying loop power to prevent reverse voltage stress on internal output transistors.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52342849995048,"sku":"CC-PAOH01 51405039-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/8C-PAIMA151454473-1751_0200f0df-99b9-496d-86c9-5e0219ecbeed.png?v=1788766428","url":"https:\/\/www.powerdcs.com\/ar\/products\/cc-paoh01-51405039-175-honeywell-hart-analog-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}