{"product_id":"cc-sdor01-51308380-175-honeywell-digital-output-relay-module","title":"CC-SDOR01 51308380-175 | Honeywell | Digital Output Relay Module","description":"\u003cp\u003eConfigured for discrete load switching and interlock execution in Experion PKS Series C platforms, the \u003cstrong\u003eHoneywell CC-SDOR01 51308380-175\u003c\/strong\u003e (\u003cstrong\u003eCC-SDOR01\u003c\/strong\u003e Digital Output Relay Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-SDOR01 51308380-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5 kg (Shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series C module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC backplane bus supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51308380-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDry contact relay channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eIOTA carrier installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGalvanic Isolation \u0026amp; Discrete Output Switching Channels\u003c\/h3\u003e\n\u003cp\u003eThe CC-SDOR01 digital output relay module uses electromechanical relay contacts to isolate high-voltage field actuator circuits from internal backplane logic. Galvanic isolation buffers across individual channel paths prevent electrical transients, inductive spikes, and ground potential differentials from propagating into central process control hardware. Integrated snubber networks and contact suppression components maintain signal integrity during continuous inductive load switching.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the output channels on the CC-SDOR01 be hot-swapped while field loads are energized?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CC-SDOR01 supports hot-swapping on its designated Series C IOTA base, provided active relay contact current limits are maintained within specified thermal safety thresholds during module insertion.\u003c\/p\u003e\n\u003cp\u003eQ: How does the CC-SDOR01 protect backplane processing logic from field-side electrical surges?\u003c\/p\u003e\n\u003cp\u003eA: Internal galvanic isolation transformers and optocouplers isolate backplane logic circuits from the output relay contacts, preventing voltage spikes on field cables from damaging the module core.\u003c\/p\u003e\n\u003cp\u003eQ: What power source energizes the internal relay coil drivers on the CC-SDOR01?\u003c\/p\u003e\n\u003cp\u003eA: Relay driver circuitry draws power directly from redundant 24 VDC rails integrated into the Series C Input\/Output Termination Assembly (IOTA) carrier.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAlign the CC-SDOR01 module with the guide rails on the Series C IOTA position and push firmly until the locking mechanisms engage.\u003c\/li\u003e\n\u003cli\u003eRoute external AC\/DC field wiring through separate conduits, maintaining physical isolation from low-level analog and communication cabling.\u003c\/li\u003e\n\u003cli\u003eConnect field cable shields directly to the cabinet single-point ground bus using short, low-impedance ground straps.\u003c\/li\u003e\n\u003cli\u003eVerify external load current ratings to ensure field switching circuits do not exceed maximum contact current boundaries.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52342871490856,"sku":"CC-SDOR01 51308380-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-SDOR01_Cocoai.png?v=1788767756","url":"https:\/\/www.powerdcs.com\/ar\/products\/cc-sdor01-51308380-175-honeywell-digital-output-relay-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}