{"product_id":"cc-taox51-honeywell-experion-pks-series-c-hart-analog-output-module","title":"CC-TAOX51 Honeywell Experion PKS Series-C HART Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAOX51\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-PAOH51\u003c\/strong\u003e (part number \u003cstrong\u003e51307078-100\u003c\/strong\u003e) HART Analog Output Module, operates as a dedicated hardware component for converting controller commands into precise analog field loops within Experion PKS Series-C platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAOX51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 85 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51307078-100 \/ CC-PAOH51 Rev A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eRS485, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and system isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and 4-20 mA HART Loop Protocol Execution\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TAOX51 provides physical termination assembly paths utilizing a 4-20 mA current drive topology across 16 independent channels supporting the 4-20 mA HART loop protocol. The layout embeds functional channel-to-channel isolation networks alongside dedicated system-side galvanic boundaries to block high-voltage transient spikes originating in the field from propagating back to the central processing backplane. In addition to standard analog drive circuitry, the hardware incorporates onboard communication physical layers supporting RS485 and Modbus RTU protocols to facilitate auxiliary telemetry routing alongside primary process control operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the serial communication interface configured on this terminal assembly?\u003c\/p\u003e\n\u003cp\u003eA: The onboard RS485 interface utilizes Modbus RTU protocol rules to act as a localized data link, allowing upstream nodes or monitoring tools to extract real-time diagnostic states directly from the module termination assembly.\u003c\/p\u003e\n\u003cp\u003eQ: What action does the output channel execute if system communication is lost?\u003c\/p\u003e\n\u003cp\u003eA: Upon a deterministic loss of the backplane data stream, the individual channel circuits transition their respective 4-20 mA outputs to a predefined, hardware-configured fallback state or hold the last valid current value until CPU communication resumes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSnap the assembly onto the standard industrial DIN rail within the local enclosure, checking that both top and bottom tension clips are fully engaged to prevent mechanical shifting.\u003c\/li\u003e\n\u003cli\u003eTerminate all 4-20 mA loop shield drains at a single common ground bus inside the cabinet, keeping the outer shield jacket continuously insulated throughout the conduit path to prevent ground loop offsets.\u003c\/li\u003e\n\u003cli\u003eConfirm that the aggregate power dissipation of adjacent DIN rail components does not exceed the structural cooling capabilities of the cabinet layout, leaving a minimum vertical clearance zone above the assembly to permit unhindered airflow.\u003c\/li\u003e\n\u003cli\u003eRoute field output signal cables through dedicated wire raceways separated from AC power conductors by at least 200 mm to prevent electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring connections comply with the terminal assignments for the corresponding 16-channel analog output arrangement before energizing loop power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52357338267944,"sku":"CC-TAOX51","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-TAOX51_Cocoai.png?v=1788939709","url":"https:\/\/www.powerdcs.com\/ar\/products\/cc-taox51-honeywell-experion-pks-series-c-hart-analog-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}