CC-TDOB11 51308373-175 Honeywell Digital Output Module

Specifications

  • Manufacturer: Honeywell

  • Product No.: CC-TDOB11 51308373-175

  • Condition: 10 العناصر الموجودة في المخزون

  • Product Type: Digital Output Modules

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 520g

  • Shipping port: Xiamen

  • Warranty: 12 months

تفاصيل المنتج

وصف

The Honeywell CC-TDOB11 51308373-175, also cataloged as the CC-TDOB11 Digital Output Module, operates as a dedicated hardware component for discrete 24 VDC signal switching and field actuation execution within Honeywell Experion PKS Series C DCS platforms. It drives solenoid valves, interposing relays, and status indicators directly from the system backplane bus.

Hardware Specifications

Parameter Specification
Model CC-TDOB11
Part Number 51308373-175
Brand Honeywell
Origin USA
Weight 0.52 kg
Dimensions 30 x 21.6 x 2.3 cm
Operating Temp Standard industrial operating range
Power Consumption System backplane and 24 VDC bus powered
Output Type Digital Output 24 VDC
System Compatibility Honeywell Experion PKS Series C DCS
Network Interface Integrated backplane route to Ethernet controller interface

Channel-to-Channel Isolation & Signal Isolation

The Honeywell CC-TDOB11 module incorporates dedicated galvanically isolated channels to prevent cross-talk and transient voltage spikes from reaching the primary controller logic. Internal optocouplers decouple field-side 24 VDC switching noise from the internal processing core. Channel-to-channel and channel-to-system isolation barriers protect the backplane from ground loops, field wiring faults, and induced electromagnetic interference across long control loop runs.

Frequently Asked Questions

Q: Can the CC-TDOB11 digital output module be hot-swapped while the IOTA rack remains powered?

A: Yes. The module supports live insertion and removal (hot-swapping) on an active I/O Termination Assembly (IOTA) without interrupting backplane communication or disturbing neighboring active modules.

Q: How does the module handle output circuit short circuits or field overload conditions?

A: The digital output circuitry incorporates current-limiting mechanisms and channel isolation designed to isolate field faults, preventing localized electrical shorts from compromising the entire backplane assembly.

Q: Is external 24 VDC field wiring wired directly to the front face of the module?

A: No. Field power wiring and signal output conductors connect directly to the underlying IOTA terminal blocks. The CC-TDOB11 module establishes electrical connectivity via robust backplane pin connectors upon mechanical installation.

Field Installation Guidelines

  1. Power down the corresponding field circuit loop power if required by site safety protocols prior to mechanical installation.
  2. Align the CC-TDOB11 module PCB edge connectors with the designated card guides on the Honeywell Series C IOTA board.
  3. Slide the module into the slot until the multi-pin backplane connectors seat completely into the IOTA mating header.
  4. Secure any integrated mechanical retention screws to maintain solid grounding and vibration resistance.
  5. Confirm that all field cabling tied to the IOTA terminal strips utilizes single-point shield grounding to avoid ground loop current interference.

كيفية الحصول على عرض أسعار