{"product_id":"cc-tuio31-honeywell-experion-pks-series-c-universal-i-o-iota-board","title":"CC-TUIO31 Honeywell Experion PKS Series C Universal I\/O IOTA Board","description":"\u003cp\u003eConfigured for field signal termination and routing in Experion PKS Series C automation platforms, the \u003cstrong\u003eHoneywell CC-TUIO31\u003c\/strong\u003e (\u003cstrong\u003eCC-TUIO31\u003c\/strong\u003e Universal I\/O Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TUIO31 (Part Number: 51306875-176)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C housing environmental tolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive field termination assembly (0 W internal logic dissipation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e32 universal channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubstrate Protection\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C C300 I\/O system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eUniversal I\/O Termination Assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe CC-TUIO31 Universal Input Output Termination Assembly (UIOTA) connects field instruments directly to the matching Series C Universal I\/O Module (UIOM). Built to handle software-configurable channels—including 4-20 mA HART loop protocol instruments, digital inputs, and digital outputs—the assembly incorporates galvanic channel-to-channel isolation. This electrical boundary suppresses common-mode noise, prevents ground loop currents, and isolates field-induced transients from reaching internal processing circuitry.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can an active Universal I\/O Module be replaced without disconnecting field conductors from the CC-TUIO31 board?\u003c\/p\u003e\n\u003cp\u003eA: Yes, field wiring remains connected to the CC-TUIO31 board terminals, allowing the associated active Universal I\/O Module to be hot-swapped online without disturbing field loops.\u003c\/p\u003e\n\u003cp\u003eQ: How are individual channel operational types assigned on the CC-TUIO31 hardware?\u003c\/p\u003e\n\u003cp\u003eA: Channel modes (analog input, analog output, digital input, digital output) are assigned via software in the Experion PKS Control Builder, requiring no physical jumpers on the board.\u003c\/p\u003e\n\u003cp\u003eQ: Does the CC-TUIO31 terminal assembly require direct power connection?\u003c\/p\u003e\n\u003cp\u003eA: No, the board functions as a passive interface; field instrument loop power is supplied via the backplane connections through the attached I\/O module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eLock the CC-TUIO31 assembly onto the Series C vertical DIN rail channel until all retaining clips fully engage.\u003c\/li\u003e\n\u003cli\u003eTerminate field signal conductors to the removable screw terminal blocks using recommended wire stripping lengths and torque specifications.\u003c\/li\u003e\n\u003cli\u003eGround all signal cable shield drains directly to the cabinet earth grounding bar to prevent electromagnetic interference (EMI) from coupling into analog loops.\u003c\/li\u003e\n\u003cli\u003eAlign the multi-pin interface of the Universal I\/O Module with the CC-TUIO31 board header and push firmly until fully seated.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52364585664808,"sku":"CC-TUIO31 51306875-176","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-TDIL0151308386-175_31b86efb-7f03-4140-b10a-1a9a3cc14ce4.png?v=1789023958","url":"https:\/\/www.powerdcs.com\/ar\/products\/cc-tuio31-honeywell-experion-pks-series-c-universal-i-o-iota-board","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}