{"product_id":"fbm203-rh914sv-foxboro-rtd-input-module","title":"FBM203 RH914SV | Foxboro | RTD Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eFBM203 RH914SV\u003c\/strong\u003e is a Foxboro 8-channel isolated RTD input module for industrial temperature monitoring across platinum, nickel, and copper sensors. Supporting 2-wire and 3-wire RTDs over 0 to 320 Ohm with +-0.03% of span accuracy, it operates on 24 VDC (3 W max) from -40 deg C to +70 deg C and weighs 0.4 kg.\u003c\/p\u003e\n\u003ch3\u003eRTD Sensors, Wiring, and Noise Rejection\u003c\/h3\u003e\n\u003cp\u003eEach of the eight channels on the \u003cstrong\u003eFBM203 RH914SV\u003c\/strong\u003e independently reads platinum, nickel, or copper RTD inputs across a 0 to 320 Ohm resistance range. Support for both 2-wire and 3-wire RTD configurations allows matching to existing sensor wiring, though 3-wire connections help compensate for lead-wire resistance where lead length affects accuracy.\u003c\/p\u003e\n\u003cp\u003eGalvanic isolation separates each channel from all other channels and from ground, reducing ground loop paths and shared-reference errors. At 50 Hz or 60 Hz power line frequencies, common-mode rejection exceeds 125 dB and normal-mode rejection exceeds 95 dB to suppress line-frequency interference.\u003c\/p\u003e\n\u003ch3\u003ePower, Thermal, and Mechanical Limits\u003c\/h3\u003e\n\u003cp\u003eThe module operates at 24 VDC, with a redundant input voltage range of 24 VDC (+5%, -10%) and a maximum power consumption and heat dissipation of 3 W. Factor the 3 W thermal load and redundant supply tolerance into cabinet power and cooling calculations.\u003c\/p\u003e\n\u003cp\u003ePhysical dimensions are 20 cm x 6.2 cm x 15 cm with a weight of 0.4 kg. Operating temperature spans -40 deg C to +70 deg C (-40 deg F to +158 deg F), storage spans -40 deg C to +85 deg C, and relative humidity is rated from 5% to 95%, non-condensing.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFBM203 RH914SV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e8-Channel Isolated RTD Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Input Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels, galvanically isolated per channel from other channels and ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported RTD Types\u003c\/td\u003e\n\u003ctd\u003ePlatinum, Nickel, Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e0 to 320 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003e2-wire and 3-wire RTD sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+-0.03% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 125 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 95 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (Redundant)\u003c\/td\u003e\n\u003ctd\u003e24 VDC (+5%, -10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e3 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C (-40 deg F to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e20 cm x 6.2 cm x 15 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Which RTD sensor types and wiring styles does the Foxboro FBM203 RH914SV support?\u003c\/p\u003e\n\u003cp\u003eA: It supports platinum, nickel, and copper RTD sensors in 2-wire or 3-wire configurations over a 0 to 320 Ohm range. Confirm sensor type, RTD curve\/scaling, and lead-wire configuration in your control system setup before commissioning.\u003c\/p\u003e\n\u003cp\u003eQ: How does channel isolation and noise rejection help temperature measurements on the FBM203 RH914SV?\u003c\/p\u003e\n\u003cp\u003eA: Each channel is galvanically isolated from other channels and ground, with \u0026gt; 125 dB common-mode rejection and \u0026gt; 95 dB normal-mode rejection at 50 Hz or 60 Hz. Proper sensor shield and lead routing still matter in high-noise cabinets or long cable runs.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply and temperature ratings apply to the FBM203 RH914SV?\u003c\/p\u003e\n\u003cp\u003eA: It runs on 24 VDC with a redundant input range of 24 VDC (+5%, -10%) and 3 W maximum power consumption. Operating temperature is rated from -40 deg C to +70 deg C (-40 deg F to +158 deg F) with 5% to 95% non-condensing humidity.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":68236956959016,"sku":"FBM203 RH914SV","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FBM203RH914SV.png?v=1795067918","url":"https:\/\/www.powerdcs.com\/ar\/products\/fbm203-rh914sv-foxboro-rtd-input-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}