FC-BSDOL-04UNI | Honeywell | Range-Setting Module
Specifications
Manufacturer: Honeywell
Product No.: FS-BSDOL-04UNI
Condition: 10 العناصر الموجودة في المخزون
Product Type: Range-Setting Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 400g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
Configured for current sense range setting and output loop calibration in Honeywell Safety Manager SC platforms, the Honeywell FC-BSDOL-04UNI (FC-BSDOL-04UNI Range-Setting Module) provides direct physical/electrical execution across four loop-monitored output channels. It mounts directly onto the programming connectors (Px) of the I/O backplane to adjust lead breakage detection thresholds for connected output modules.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FC-BSDOL-04UNI |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.4 kg |
| Dimensions | 120 mm x 60 mm x 40 mm |
| Operating Temp | -20 to +70 deg C (-4 to +158 deg F) |
| Power Consumption | < 5 W |
| Operating Voltage | 24 VDC |
| Range Setting Resolution | Up to +/-0.596 accuracy |
| Monitored Channels | 4 loop-monitored output channels |
| Communication Interface | RS-485 |
| System Compatibility | Honeywell Safety Manager SC, SDOL systems (e.g., SDOL-0424) |
Process Control & DCS Signal Processing Characteristics
The FC-BSDOL-04UNI module integrates precise current sense adjustments to prevent false lead breakage detection in field output circuits. Built for integration with 4-20 mA HART loop protocol architectures and discrete safety driver outputs, the hardware provides channel-to-channel isolation to prevent electrical fault propagation across field wiring loops. In redundant output configurations involving SDOL-0424 modules, a single FC-BSDOL-04UNI serves both primary and secondary channels to maintain consistent range calibration across the safety system.
Frequently Asked Questions
Q: How is the FC-BSDOL-04UNI module physically mounted to the Safety Manager chassis?
A: The module connects directly to the dedicated programming connector (Px) interface on the I/O backplane without external wiring harnesses.
Q: How does the module handle range-setting operations in redundant output configurations?
A: In redundant SDOL module setups, a single FC-BSDOL-04UNI module provides unified range setting across both redundant output channels.
Q: Does the RS-485 communication interface require separate power cabling?
A: No, operating power of 24 VDC and communication paths are routed through the backplane programming connector interface.
Field Installation Guidelines
- Backplane Connection: Align the board interface with the dedicated programming connector (Px) on the Safety Manager SC backplane. Press firmly to seat the pins, ensuring no pins are bent during insertion.
- Redundancy Setup: Verify that the single FC-BSDOL-04UNI module is correctly mapped across both SDOL-0424 modules when configured for redundant output operation.
- Grounding & Shielding: Ensure the rack chassis grounding strip is connected to the cabinet earth bar to prevent common-mode electrical noise from affecting range-setting accuracy.
- Thermal Management: Maintain adequate clearance around the module to allow convective heat dissipation within the rated operating temperature limit of -20 to +70 deg C.
كيفية الحصول على عرض أسعار
تتبع الطلب
شركات الشحن
سياسة وشروط الاسترداد
شروط الضمان
منتجات ذات صله