FC-PSU-UNL2450U Honeywell Power Supply Unit

Specifications

  • Manufacturer: Honeywell

  • Product No.: FC-PSU-UNL2450U

  • Condition: 10 العناصر الموجودة في المخزون

  • Product Type: Power Supply Modules

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 660g

  • Shipping port: Xiamen

  • Warranty: 12 months

تفاصيل المنتج

وصف

Configured for high-capacity 25 VDC voltage regulation in Honeywell Experion PKS and Safety Manager platforms, the Honeywell FC-PSU-UNL2450U (FC-PSU-UNL2450U Power Supply Unit) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model FC-PSU-UNL2450U
Brand Honeywell
Weight Shipping Weight: Approx. 10 kg
Operating Temp 0 to +55 deg C
Power Consumption Input: 110/240 VAC, 50/60 Hz; Output: 25 VDC at 43 A continuous
Module Type Power Supply Unit
Input Voltage 110/240 VAC (50/60 Hz)
Output Voltage 25 VDC
Output Current 43 A continuous
Isolation Galvanic isolation between input and output circuits
Redundancy Supports parallel redundant installation
Cooling Natural convection cooling
Protection Over-voltage, over-current, and thermal protection

4-20 mA HART Loop Protocol & Channel-to-Channel Isolation

Designed for process control power infrastructure, the unit converts 110/240 VAC input power into a stabilized 25 VDC output rail capable of delivering 43 A continuous current. Internal galvanic isolation between input and output circuits prevents primary utility transients and ground noise from propagating into secondary DC distribution paths. Built-in channel-to-channel isolation across powered sub-modules mitigates loop interference, maintaining low residual ripple to preserve signal clarity for 4-20 mA HART instrumentation, process I/O buses, and safety shutdown circuits.

Frequently Asked Questions

Q: How does the unit operate within parallel redundant power configurations?

A: Integrated decoupling diodes permit direct parallel connection with a secondary FC-PSU-UNL2450U unit, allowing automatic load sharing and seamless failover to ensure uninterrupted 25 VDC delivery if one module loses AC primary power.

Q: What internal protection mechanisms prevent field-side load damage during electrical faults?

A: The supply features hardware-based over-voltage, over-current, and thermal shutdown circuits that limit fault current and automatically clamp or cut off output voltage upon detecting thermal or load limits.

Field Installation Guidelines

  • Isolate all AC mains supply voltage sources before making or altering power input wiring connections to avoid electrical shock hazards.
  • Snap or bolt the module securely into the designated enclosure rack, maintaining recommended vertical clearance to facilitate natural convection cooling.
  • Size input and output copper cabling appropriately for 43 A continuous current draw to prevent thermal line losses and conductor degradation.
  • Connect the main protective earth (PE) terminal to the cabinet central grounding bus to establish galvanic shield integrity and lightning transient protection.
  • Ensure redundant power cable pairs are routed through separated wire paths to maintain system availability during localized cabinet damage.