FC-QPP-0002 V1.2 Quad Processor | Honeywell
Specifications
Manufacturer: Honeywell
Product No.: FC-QPP-0002 V1.2
Condition: 10 العناصر الموجودة في المخزون
Product Type: CPU Processors
Product Origin: USA
Payment:T/T, Western Union
Weight: 1280g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
The Honeywell FC-QPP-0002 V1.2, also cataloged as the FC-QPP-0002 Quad Processor, operates as a dedicated hardware component for high-integrity safety logic execution and system task processing within Honeywell Safety Manager platforms. It executes application logic, evaluates field input states, and manages system backplane bus communications to drive safe control outputs.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FC-QPP-0002 V1.2 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 1.28 kg |
| Dimensions | 8.8 cm x 22.7 cm x 17.5 cm |
| Operating Temp | -20 to +60 deg C |
| Power Consumption | System backplane powered (Internal bus draw < 15 W) |
| Architecture | Quad Processor Subsystem |
| Firmware Revision | V1.2 |
| System Platform | Honeywell Safety Manager / FSC |
Process Control & DCS Signal Processing Characteristics
The FC-QPP-0002 V1.2 module incorporates high-density channel-to-channel isolation across its backplane data interfaces to prevent transient ground loops from propagating into the central logic solver. Designed to process data acquired from 4-20 mA HART loop protocol field devices and discrete I/O subsystems, the quad-processor architecture continuously cross-checks execution pathways, filtering electromagnetic interference and ensuring deterministic scan execution for critical safety loops.
Frequently Asked Questions
Q: Does the FC-QPP-0002 V1.2 support hot-swapping during active system operation?
A: Hot-swapping is supported provided the redundant secondary processor module is fully synchronized and backplane power stability is verified prior to module extraction.
Q: How does the V1.2 hardware revision impact backplane bus communication?
A: Revision V1.2 provides optimized internal bus arbitration and enhanced firmware compatibility, maintaining deterministic scan times across high-density I/O configurations.
Q: What precautions should be observed regarding ESD during installation?
A: Field service engineers must wear a grounded wrist strap attached to the cabinet ESD grounding point to prevent electrostatic discharge damage to internal processor components during insertion.
Field Installation Guidelines
- Mechanical Mounting: Align the module top and bottom card guides with the designated chassis slot in the rack frame. Gently slide the assembly inward until backplane multi-pin connectors are fully seated, then tighten the top and bottom retaining screws.
- Shielding & Grounding: Ensure the enclosure chassis is grounded to the main plant earthing system via a low-impedance copper earth bus bar. All field wiring shields connected to associated I/O racks must maintain single-point grounding.
- Power & Wiring Separation: Keep low-voltage logic signal backplane interconnects and communication lines separated from high-voltage AC power cables inside the cabinet by a minimum clearance distance of 30 cm.
- Thermal Management: Maintain unimpeded vertical air circulation above and below the module rack assembly to support natural convective cooling across the heat sinks.
كيفية الحصول على عرض أسعار
تتبع الطلب
شركات الشحن
سياسة وشروط الاسترداد
شروط الضمان
منتجات ذات صله
- يؤدي اختيار تحديد إلى تحديث كامل للصفحة.