FS-PDC-MB24-1 Honeywell Power Distribution Cable

Specifications

  • Manufacturer: Honeywell

  • Product No.: FS-PDC-MB24-1

  • Condition: 10 العناصر الموجودة في المخزون

  • Product Type: Power Distribution Cables

  • Payment:T/T, Western Union

  • Weight: 320g

  • Shipping port: Xiamen

  • Warranty: 12 months

تفاصيل المنتج

وصف

The Honeywell FS-PDC-MB24-1, also cataloged as the FS-PDC-MB24-1 Power Distribution Cable, operates as a dedicated hardware component for 24 VDC power transfer from the MB-0001 mains rail to the PDB-0824 power distribution board within Honeywell Safety Manager platforms.

Hardware Specifications

Parameter Specification
Model FS-PDC-MB24-1
Brand Honeywell
Origin USA
Weight 0.71 lbs (0.32 kg)
Dimensions 145 cm length
Operating Temp 0 deg C to +60 deg C
Power Consumption Passive distribution assembly (Zero internal power draw)
Voltage Rating 24 VDC
Source Connection MB-0001 Mains Power Rail
Destination Connection PDB-0824 Power Distribution Board
Cable Type Power Distribution Cable
System Compatibility Honeywell Safety Manager / FSC Systems

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The power cable assembly incorporates heavy-duty insulation barriers and low-resistance copper conductors to deliver stable 24 VDC operating power to downstream distribution boards. High-dielectric conductor insulation maintains physical channel-to-channel isolation between auxiliary power lines and neighboring signal conductors. This electrical separation prevents DC bus switching transients and ground potential differences from coupling into 4-20 mA HART loop protocol circuits or discrete safety I/O channels operating in the same enclosure.

Frequently Asked Questions

Q: What specific hardware modules are interconnected by the FS-PDC-MB24-1 cable?

A: The cable directly routes 24 VDC power from an MB-0001 mains power rail to a PDB-0824 power distribution board inside Safety Manager cabinets.

Q: Is live disconnection of the FS-PDC-MB24-1 cable assembly permitted during system operation?

A: No, field 24 VDC power feeding the cable must be isolated prior to disconnection to prevent electrical arcing on pin headers and unpowered dropouts on connected I/O sub-assemblies.

Q: How does the cable construction protect against noise coupling to signal wiring?

A: Thick PVC outer jacket insulation and tight conductor twisting isolate the 24 VDC power feed from inductive cross-talk with parallel field signal cables.

Field Installation Guidelines

  • De-energize the MB-0001 power source prior to connecting or removing the cable assembly.
  • Route the 145 cm cable through dedicated DC power wireways inside the cabinet, keeping it separate from high-voltage AC feeds.
  • Align the connector plugs squarely with mating header sockets on the MB-0001 rail and PDB-0824 board until retention latches engage fully.
  • Verify that cabinet protective earth (PE) grounding is secure before restoring 24 VDC power to the system.

كيفية الحصول على عرض أسعار

تتبع الطلب

شركات الشحن

سياسة وشروط الاسترداد

شروط الضمان

منتجات ذات صله