FS-PSU-UNI2450U Honeywell Power Supply Module

Specifications

  • Manufacturer: Honeywell

  • Product No.: FS-PSU-UNI2450U

  • Condition: 10 العناصر الموجودة في المخزون

  • Product Type: Power Supply Modules

  • Payment:T/T, Western Union

  • Weight: 4000g

  • Shipping port: Xiamen

  • Warranty: 12 months

تفاصيل المنتج

وصف

Configured for system rail power regulation in Honeywell Safety Manager architectures, the Honeywell FS-PSU-UNI2450U (FS-PSU-UNI2450U Power Supply Module) provides direct physical/electrical execution for 24 VDC bus stabilization and system card cage power feeding.

Hardware Specifications

Parameter Specification
Model FS-PSU-UNI2450U
Brand Honeywell
Origin USA
Weight Approx. 3.20 kg (Shipping weight: 4.00 kg)
Dimensions Standard Safety Manager power chassis module
Operating Temp -10 deg C to +60 deg C
Power Consumption 110/230 VAC input, max 1350 W load capacity
Output Voltage 24 VDC nominal
Max Output Current 50 A continuous
Protection Rating Overvoltage, overcurrent, and thermal shutdown circuits
Mounting Style Dedicated chassis slot / Power rack mount

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The FS-PSU-UNI2450U power supply module incorporates galvanic isolation barriers between main AC input lines and output DC rails. Channel-to-channel isolation references across the secondary distribution bus prevent common-mode noise propagation, eliminating voltage ripple from interfering with field-side analog telemetry executing 4-20 mA HART loop protocol transactions. High-frequency line filters attenuate industrial transient surges to preserve logic rail stability.

Frequently Asked Questions

Q: Does the FS-PSU-UNI2450U support redundant N+1 parallel power configurations?

A: Yes, integrated output decoupling diodes allow multiple FS-PSU-UNI2450U units to operate in parallel across a shared 24 VDC backplane bus for seamless fault-tolerant backup.

Q: How is thermal protection executed during continuous full-load operation?

A: Thermal monitoring circuits continuously track heatsink temperatures; an internal thermal shutdown triggers an automatic output latch-off if internal dissipation limits are exceeded.

Q: What input AC voltage range does the module accept?

A: The universal AC input stage automatically accommodates nominal 110 VAC to 230 VAC line supplies without manual jumper configuration.


Field Installation Guidelines

  • Slide the module into its designated rack guide slot and tighten retaining screws to establish low-resistance frame grounding.

  • Verify primary AC input utility breakers are isolated and tagged out prior to making field terminal connections.

  • Ensure minimum enclosure clearance above and below the module cage to facilitate passive convection cooling.

  • Inspect output bus bars for correct torque specifications to prevent terminal overheating under high current loads up to 50 A.