FS-SICC-0001/L3 | Honeywell | System Interconnection Cable For Chassis IO
Specifications
Manufacturer: Honeywell
Product No.: FS-SICC-0001/L3
Condition: 10 العناصر الموجودة في المخزون
Product Type: Cable Assemblies
Payment:T/T, Western Union
Weight: 2000g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
The Honeywell FS-SICC-0001/L3, also cataloged as the FS-SICC-0001 System Interconnection Cable For Chassis IO, operates as a dedicated hardware component for high-integrity chassis I/O signal routing and termination interface execution within Honeywell Safety Manager platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FS-SICC-0001/L3 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 2.00 kg (Shipping weight) |
| Dimensions | Outer diameter 9.93 mm (0.39 in) x 3 m length |
| Operating Temp | -20 deg C to +60 deg C |
| Power Consumption | Passive interconnect assembly (Zero internal power draw) |
| Cable Construction | 20 x AWG 22 (0.34 mm2) conductors |
| Shielding Type | Double-shielded foil and braided conductor assembly |
| Cable Length | 3 m |
| System Compatibility | Honeywell Safety Manager / FSC Chassis I/O |
4-20 mA HART Loop Protocol and Channel-to-Channel Isolation
The 20-conductor AWG 22 cable construction utilizes double-shielded braid and foil protection to enforce channel-to-channel isolation principles across interconnect paths. This multi-layer shielding prevents capacitive cross-talk and high-frequency noise insertion when routing field instrumentation lines alongside chassis I/O. The assembly preserves analog telemetry integrity for 4-20 mA HART loop protocol transmitters and safety shutdown logic paths linked between chassis racks and termination units.
Frequently Asked Questions
Q: What physical conductor configuration is utilized within the FS-SICC-0001/L3 assembly?
A: The assembly contains 20 individual AWG 22 (0.34 mm2) conductors enclosed within a overall double-shielded jacket measuring 9.93 mm in outer diameter.
Q: Can this cable be disconnected while the host chassis I/O system is actively powered?
A: Unplugging the cable disrupts active signals passing through the corresponding 20-pin channel interface; connected field loops or safety channels must be bypassed prior to disconnection.
Q: How does double-shielding impact performance over the 3 m distance?
A: The combination of foil and braided shielding attenuates external electromagnetic interference (EMI), suppressing signal degradation and induced voltage spikes across the 3 m length.
Field Installation Guidelines
- Route the cable assembly through dedicated low-voltage instrument wireways, maintaining separation from high-voltage AC conductors.
- Observe a minimum bending radius of 60 mm during installation to prevent deformation of the outer jacket and damage to internal foil shielding.
- Seat the factory-terminated connectors fully into the chassis I/O slot and secure retention latches or screws to maintain low contact resistance.
- Ensure the shield drain wire connects directly to the cabinet protective earth (PE) grounding bar at a single termination point to eliminate ground loops.
كيفية الحصول على عرض أسعار
تتبع الطلب
شركات الشحن
سياسة وشروط الاسترداد
شروط الضمان
منتجات ذات صله
- يؤدي اختيار تحديد إلى تحديث كامل للصفحة.