FS-SICC-0001/L6 | Honeywell | System Interconnection Cable
Specifications
Manufacturer: Honeywell
Product No.: FS-SICC-0001/L6
Condition: 10 العناصر الموجودة في المخزون
Product Type: System Interconnection Cables
Product Origin: USA
Payment:T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
The Honeywell FS-SICC-0001/L6, also cataloged as the FS-SICC-0001 System Interconnection Cable, operates as a dedicated hardware component for high-integrity inter-rack signal routing and subsystem communication within Honeywell Safety Manager platforms. It links central logic solvers to remote field termination assemblies across a 6 m cable span.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FS-SICC-0001/L6 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.2 kg |
| Dimensions | 12.4 cm x 12.6 cm x 2.2 cm |
| Operating Temp | -20 to +60 deg C |
| Power Consumption | Passive interconnect assembly (Zero internal power draw) |
| Cable Type | System Interconnection Cable |
| Cable Length | 6 m (indicated by /L6 suffix) |
| System Compatibility | Honeywell Safety Manager / Experion PKS |
Process Control & DCS Signal Interconnection Characteristics
The FS-SICC-0001/L6 cable assembly incorporates channel-to-channel isolation principles to preserve signal integrity between central control racks and remote field termination assemblies (FTAs). Featuring integrated foil and braided shielding, the cable suppresses high-frequency electromagnetic interference and eliminates ground loop current flows across cabinet boundaries. The physical copper conductor matrix supports deterministic, low-attenuation routing of discrete safety signals and 4-20 mA HART loop protocol telemetry over the 6 m length.
Frequently Asked Questions
Q: What precautions apply when disconnecting the FS-SICC-0001/L6 cable during active system execution?
A: Disconnections during live system operation are permissible only within redundant communication loops. Removing an active single-channel interconnection cable will immediately sever signal feedback to the Safety Manager logic solver.
Q: How is the cable shield grounded to ensure signal noise suppression?
A: The integral shield drain wire must be bonded to the main cabinet ground bus at a single reference point to prevent circulating ground currents from inducing noise on low-voltage analog channels.
Field Installation Guidelines
- Routing & Bending Limits: Route the cable through dedicated wire troughs away from high-voltage cables. Maintain a minimum static bending radius of 50 mm to prevent conductor degradation and shield tearing.
- Connector Engagement: Align connector pins precisely with the backplane or FTA mating header. Fully tighten all mechanical retention screws to maintain a vibration-proof connection.
- Shield Grounding: Connect the shield drain wire directly to the cabinet ground bar using low-impedance earthing clamps.
- Physical Separation: Maintain a minimum physical distance of 30 cm between the system interconnection assembly and AC power distribution conductors within the enclosure.