{"product_id":"fs-sicc-001-l8-in-system-interconnection-cable-honeywell","title":"FS-SICC-001\/L8-IN System Interconnection Cable | Honeywell","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-SICC-001\/L8-IN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFS-SICC-001\u003c\/strong\u003e System Interconnection Cable, operates as a dedicated hardware component for multi-conductor signal interface routing between Field Termination Assemblies (FTAs) and input I\/O modules within Honeywell Safety Manager platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-SICC-001\/L8-IN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8 m (26.2 ft) overall length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive physical conductor assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eSystem Interconnection Cable (SIC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eInput (IN) module pinout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eBraided metallic shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Type\u003c\/td\u003e\n\u003ctd\u003eMulti-conductor, twisted pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e10x cable diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; 4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe pre-terminated multi-conductor twisted pair geometry minimizes electromagnetic cross-talk between adjacent input circuits across the 8-meter span. High line isolation and overall braided shielding prevent external electrical field transients from inducing measurement errors on connected 4-20 mA HART loop protocol analog input channels. This physical shielding topology preserves low-level signal fidelity and maintains accurate reference values across system cold junction compensation (CJC) circuits without introducing ground loop shifts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What key mechanical difference distinguishes \"IN\" configured SIC cables from \"OUT\" variants?\u003c\/p\u003e\n\u003cp\u003eA: The \"IN\" designation specifies wiring pinouts and color coding optimized specifically for digital and analog input modules, preventing miswiring to output terminals.\u003c\/p\u003e\n\u003cp\u003eQ: How does the braided shielding construction affect field grounding practices?\u003c\/p\u003e\n\u003cp\u003eA: The outer braided shield provides continuous EMI protection and must be bonded to a single-point chassis ground bar at one cable end to prevent circulating ground loops.\u003c\/p\u003e\n\u003cp\u003eQ: What physical bend limits must be observed during cable installation inside wireways?\u003c\/p\u003e\n\u003cp\u003eA: The assembly requires a minimum bend radius of at least 10 times the overall cable outer diameter to prevent internal conductor strain or shield deformation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePlan cabinet wiring pathways to ensure the cable route maintains a minimum bend radius of 10 times the outer cable diameter.\u003c\/li\u003e\n\u003cli\u003eSeat the pre-terminated factory connector firmly into the matching System Interconnection Cable (SIC) port on the Field Termination Assembly (FTA).\u003c\/li\u003e\n\u003cli\u003eConnect the opposite cable connector to the designated input module interface slot until keying latches fully engage.\u003c\/li\u003e\n\u003cli\u003eBond the cable shield to the cabinet frame at a single ground point to eliminate differential earth loop currents.\u003c\/li\u003e\n\u003cli\u003eSecure the cable harness with strain-relief tie wraps along wireway brackets to remove physical tension from connector heads.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52407077273896,"sku":"FS-SICC-001\/L8-IN","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FS-SICC-001L8-IN.jpg?v=1789720184","url":"https:\/\/www.powerdcs.com\/ar\/products\/fs-sicc-001-l8-in-system-interconnection-cable-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}