Honeywell 51202329-722 I/O Link Cable Pair
Specifications
Manufacturer: Honeywell
Product No.: 51202329-722
Condition: 10 العناصر الموجودة في المخزون
Product Type: I/O Link Cables
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
Configured for signal routing and communication interconnection in Experion control networks, the Honeywell 51202329-722 (51202329-722 I/O Link Cable Pair) provides direct physical signal execution and power transmission across distributed nodes.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 51202329-722 |
| Brand | Honeywell |
| Origin | United States |
| Weight | 0.3 kg (estimated) |
| Dimensions | 36 inches length (each cable) |
| Operating Temp | -40 deg C to 85 deg C |
| Power Consumption | Passive cabling component |
| Voltage Rating | 300 V |
| Conductor Configuration | 4 conductors, 12 AWG, shielded |
| Cable Type | I/O Link cable pair |
Honeywell DCS Process Control and Signal Communication
The assembly integrates within Honeywell Experion process automation architecture, maintaining strict channel-to-channel isolation and cold junction compensation (CJC) path integrity across distributed nodes. Standard configuration supports 4-20 mA HART loop protocol environments alongside high-speed digital communication layers. The integrated shielding minimizes electromagnetic interference (EMI) across noisy industrial floors, ensuring deterministic bus operation and low-latency packet transmission between field devices and master controller cards.
Frequently Asked Questions
Q: Does the 51202329-722 support hot-swapping on active controller networks?
A: Cabling adjustments must be performed with upstream loop power isolated to prevent communication dropouts or transient voltage spikes on connected control nodes.
Q: What conductor gauge and voltage rating are specified for this cable pair?
A: The assembly features 12 AWG conductors rated for up to 300 V under standard operating conditions.
Field Installation Guidelines
- Verify that system power and communication loops are de-energized prior to routing and connecting the cable between controller nodes and interface modules.
- Route the 36-inch cables along designated internal cabinet wireways, maintaining physical separation from high-voltage AC power lines to prevent induced noise coupling.
- Secure connector plugs firmly to terminal interfaces, ensuring locking mechanisms or retention screws are fully engaged to withstand industrial vibration environments.
كيفية الحصول على عرض أسعار
تتبع الطلب
شركات الشحن
سياسة وشروط الاسترداد
شروط الضمان
منتجات ذات صله
- يؤدي اختيار تحديد إلى تحديث كامل للصفحة.