Honeywell 51304638-175 MC-GOAX02 Analog Output Galvanic Isolator Assembly
Specifications
Manufacturer: Honeywell
Product No.: MC-GOAX02 51304638-175
Condition: 10 العناصر الموجودة في المخزون
Product Type: Analog Output Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
The Honeywell 51304638-175, also cataloged as the MC-GOAX02 Analog Output Galvanic Isolator Assembly, operates as a dedicated hardware component for isolated signal conversion and ground loop elimination within Experion PKS, TPS/TDC 3000, and FSC platform environments. It converts digital control commands into 2 isolated 4-20 mA or 0-10 VDC output loops to drive actuators and control valves with ±0.1% full-scale accuracy.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | MC-GOAX02 (51304638-175) |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.1 kg (Net) / 0.5 kg (Shipping) |
| Dimensions | 2.2 cm x 12.4 cm x 12.6 cm |
| Operating Temp | -20 to 70 deg C |
| Power Consumption | 24 VDC (Nominal) |
| Subsystem Type | Analog Output Galvanic Isolator Assembly |
| Channel Count | 2 Isolated Channels |
| Signal Formats | 4-20 mA current loop / 0-10 VDC (configurable) |
| Isolation | Full Channel-to-Channel and Channel-to-System |
| System Compatibility | Experion PKS, TPS/TDC 3000, FSC Platforms |
Channel-to-Channel Isolation & Galvanic Protection
The MC-GOAX02 (51304638-175) incorporates full transformer-based galvanic isolation across both individual output channels and between the field-side wiring and internal system buses. This physical barrier blocks common-mode voltage spikes, preventing stray ground potentials from corrupting control logic. The isolated output stage delivers clean analog signals across active 4-20 mA HART loop protocol networks, safeguarding controller backplane components during field cable short circuits or electrical fault conditions.
Frequently Asked Questions
Q: Can individual channels on the MC-GOAX02 be hot-swapped or reconfigured without disrupting the adjacent channel?
A: Module replacement must follow system rack de-energization or IOTA isolation procedures, while output signal selection (4-20 mA or 0-10 VDC) requires configuring dedicated module terminals or firmware setup.
Q: How does the galvanic isolation circuit prevent ground loop degradation in analog control valves?
A: By breaking the direct physical earth connection between field actuator loops and system power supplies, the assembly blocks ground loop current paths that introduce offset errors into the 4-20 mA drive signal.
Field Installation Guidelines
- Mount the module securely onto the designated cabinet DIN rail or cabinet-integrated IOTA base to establish proper mechanical retaining force.
- Verify 24 VDC main power supply polarity before applying power to prevent internal reversed-polarity protective fuse tripping.
- Route field wiring for 4-20 mA loops using twisted-shielded pair cables, terminating shields at a single chassis grounding point.
- Maintain separation between low-voltage analog signal cables and high-voltage AC power conductors within panel wire raceways.
كيفية الحصول على عرض أسعار