Honeywell 8C-PDODA1 51454472-175 Series 8 Digital Output Module
Specifications
Manufacturer: Honeywell
Product No.: 8C-PDODA1 51454472-175
Condition: 10 العناصر الموجودة في المخزون
Product Type: Digital Output Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
Configured for discrete signal transmission to actuators, solenoids, and interlock relays in Experion PKS Series 8 platforms, the Honeywell 8C-PDODA1 51454472-175 (8C-PDODA1 Digital Output Module) provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 8C-PDODA1 51454472-175 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.3 kg |
| Dimensions | 61 mm x 153 mm x 144 mm |
| Operating Temp | Unspecified (-40 to +70 deg C standard industrial class) |
| Power Consumption | 95 mA |
| Part Number | 51454472-175 |
| Module Type | Digital Output Module |
| Channels | 16 discrete output channels |
| Output Voltage | 24 VDC |
| Channel Load Capacity | 0.5 A maximum per channel |
| Mounting | Series 8 chassis / IOTA carrier |
Channel Isolation & Bus Loop Protocols
The 8C-PDODA1 51454472-175 module processes command bits from the C300 controller via the Series 8 internal backplane bus, energizing up to 16 independent 24 VDC output channels. Integrated channel-to-channel isolation safeguards sensitive backplane logic against reverse electromotive force (EMF) generated by inductive field loads such as heavy-duty solenoids or mechanical relays. Internal short-circuit protection and current-limiting networks isolate individual fault conditions to prevent single-point failures from compromising adjacent module channels or the main backplane supply.
Frequently Asked Questions
Q: What is the maximum current capacity per individual channel on the 8C-PDODA1 51454472-175?
A: Each individual 24 VDC digital output channel supports a continuous maximum load current of 0.5 A.
Q: Can an 8C-PDODA1 51454472-175 module be hot-swapped during active controller operations?
A: Yes, hot-swapping is supported on the Series 8 IOTA carrier slot without interrupting power or signal flow to adjacent I/O modules.
Q: Does the 8C-PDODA1 51454472-175 require external field power for driving inductive loads?
A: The module relies on 24 VDC field power routed through the IOTA terminal block to drive external output devices up to the per-channel amperage rating.
Field Installation Guidelines
- IOTA Mounting: Align the module bottom connector headers with the target Series 8 IOTA carrier position and apply uniform downward pressure until the dual mechanical retaining latches fully lock.
- Shield & Grounding: Terminate overall cable shields at a single earthing point on the main enclosure ground bar to prevent circulating ground currents from interfering with discrete state switching.
- Wiring Separation: Route 24 VDC discrete output control lines in dedicated cabinet raceways physically separated from high-voltage AC cables and variable frequency drives (VFDs).
كيفية الحصول على عرض أسعار