{"product_id":"honeywell-8c-taidb1-51307133-175-series-8-interface-module-backplane","title":"Honeywell 8C-TAIDB1 51307133-175 Series 8 Interface Module Backplane","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-TAIDB1 51307133-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8C-TAIDB1\u003c\/strong\u003e Interface Module Backplane, operates as a dedicated hardware component for internal bus power distribution and signal routing within Honeywell Experion PKS Series 8 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TAIDB1 51307133-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10 cm x 18 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eUnspecified (-40 to +70 deg C standard industrial class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eUnspecified (24 VDC, 5 VDC, 3.3 VDC, 1.2 VDC internal power rails)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51307133-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterface Module Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Signal Compatibility\u003c\/td\u003e\n\u003ctd\u003eAnalog, Digital, and Specialty I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS Series 8 \/ C300 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Backplane Galvanic Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 8C-TAIDB1 51307133-175 provides the physical and electrical backplane infrastructure required to route power rails (24 VDC, 5 VDC, 3.3 VDC, and 1.2 VDC) and digital communication signals between the C300 controller and installed I\/O modules. The backplane bus traces maintain galvanic channel-to-bus isolation across slots to prevent field-induced ground loops and electrical surges from damaging internal logic hardware. When hosting analog I\/O modules, the backplane signal pathways preserve bidirectional 4-20 mA HART loop protocol pass-through communication, transferring field device diagnostics directly to the control network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What internal system voltage rails are supplied across the 8C-TAIDB1 51307133-175 backplane bus?\u003c\/p\u003e\n\u003cp\u003eA: The backplane board distributes 24 VDC, 5 VDC, 3.3 VDC, and 1.2 VDC power rails to energize mounted interface modules and internal bus transceivers.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 8C-TAIDB1 51307133-175 support hot-swapping of installed I\/O modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes, module slots feature power-sequenced edge connectors that allow removal and insertion under power (RIUP) of individual I\/O modules without interrupting backplane bus traffic on adjacent slots.\u003c\/p\u003e\n\u003cp\u003eQ: How does the backplane protect against field-side electrical interference?\u003c\/p\u003e\n\u003cp\u003eA: Signal trace architecture incorporates integrated channel-to-bus galvanic isolation barriers, preventing ground potential variations and voltage transients from reaching the C300 controller.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Chassis Mounting\u003c\/strong\u003e: Secure the backplane frame onto the cabinet mounting plate using appropriate hardware, verifying correct alignment before latching corresponding I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Frame Grounding\u003c\/strong\u003e: Connect the dedicated earth ground lug on the backplane assembly to the central cabinet copper earth bar using a low-impedance conductor to ensure effective transient surge dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Harness Routing\u003c\/strong\u003e: Separate internal system power supply cables and field I\/O wiring runways from high-voltage AC conductors to maintain signal integrity across backplane data lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52312980160808,"sku":"8C-TAIDB1 51307133-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/8C-TAIDA1_719ac410-24c6-489c-81ad-4b41fe01c808.png?v=1788256438","url":"https:\/\/www.powerdcs.com\/ar\/products\/honeywell-8c-taidb1-51307133-175-series-8-interface-module-backplane","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}