Honeywell 900P24-0101 Expansion Processor Module
Specifications
Manufacturer: Honeywell
Product No.: 900P24-0101
Condition: 10 العناصر الموجودة في المخزون
Product Type: Expansion Processor Modules
Payment:T/T, Western Union
Weight: 2000g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
Configured for expansion processing and power management within ControlEdge HC900 controller architectures, the Honeywell 900P24-0101, also cataloged as the 900P24-0101 Expansion Processor Module, provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 900P24-0101 |
| Brand | Honeywell |
| Origin | Standard Industrial Manufacturing |
| Weight | Standard module weight class (Shipping weight: 2.0 kg) |
| Dimensions | Standard ControlEdge rack module profile |
| Operating Temp | Standard industrial cabinet range |
| Power Consumption | 72.5 W max input rating |
| Input Voltage | 21 to 29 VDC |
| Current Rating | 5 A max continuous |
| Inrush Current | 30 A for 3 ms at 29 VDC |
Channel-To-Channel Isolation And Loop Protocol Integrity
The expansion processor module incorporates galvanic isolation barriers between primary DC input terminals and internal bus rails to prevent common-mode noise and high-voltage transients from propagating across the backplane. It supports downstream 4-20 mA HART loop protocol power distribution requirements across connected I/O expansion cards without introducing ground loops. Integrated internal voltage regulation circuitry, inrush current suppression (30 A for 3 ms), and cold junction compensation (CJC) reference stabilization protect system processing nodes against line voltage fluctuations and thermal drift.
Frequently Asked Questions
Q: Can the 900P24-0101 expansion processor module be hot-swapped while the ControlEdge HC900 rack is powered?
A: No. System power and rack supply feeds must be isolated and locked out before inserting or extracting the module from the chassis backplane to prevent bus communication faults or terminal pin damage.
Q: What precautions should be taken prior to unseating the module from the rack?
A: Main DC input power feeding the cabinet distribution panel must be completely isolated, locked out, and tagged out before disconnecting wiring harnesses or unseating the unit.
Field Installation Guidelines
- Verify that primary DC input power is isolated, locked out, and tagged out prior to handling or wiring the module.
- Mount the unit securely in the designated rack slot of the ControlEdge system, ensuring firm mechanical engagement with backplane power and communication pins.
- Check input terminals and power wiring connections for secure mechanical clamping and proper insulation before energizing.
- Measure operating input voltage ranges (21 to 29 VDC) using a calibrated digital multimeter to verify correct supply parameters prior to system startup.
كيفية الحصول على عرض أسعار
تتبع الطلب
شركات الشحن
سياسة وشروط الاسترداد
شروط الضمان
منتجات ذات صله
- يؤدي اختيار تحديد إلى تحديث كامل للصفحة.