{"product_id":"honeywell-900rtr-h001-controledge-hc900-remote-terminal-panel","title":"Honeywell 900RTR-H001 ControlEdge HC900 Remote Terminal Panel","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900RTR-H001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e900RTR\u003c\/strong\u003e Remote Terminal Panel, operates as a dedicated hardware component for relay output signal distribution and cabinet wiring field termination within ControlEdge HC900 systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900RTR-H001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRemote Terminal Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eRemote Terminal Panel for Relay Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e5 to 250 VDC, 24 to 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e2 A at 30 VDC, 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eGreater than 100 MΩ at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe remote terminal panel interfaces relay output channels to field final control elements through galvanically isolated signal routing circuits. Built-in high insulation resistance barriers prevent channel-to-channel isolation degradation under fluctuating electrical load conditions, supporting 4-20 mA HART loop protocol secondary control loops and high-voltage AC\/DC contact execution without cross-channel noise coupling across HC900 backplane interfaces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the 900RTR-H001 compatible with all HC900 I\/O modules?\u003c\/p\u003e\n\u003cp\u003eA: No, the 900RTR-H001 is specifically engineered for coupling with HC900 relay output modules; cross-referencing system schematics is required prior to deployment with digital or analog I\/O cards.\u003c\/p\u003e\n\u003cp\u003eQ: What insulation resistance rating is maintained by the terminal panel circuits?\u003c\/p\u003e\n\u003cp\u003eA: The board maintains an insulation resistance exceeding 100 MΩ measured at 500 VDC to prevent current leakage between high-voltage switching channels.\u003c\/p\u003e\n\u003cp\u003eQ: Does the unit require external DC operating power to drive internal logic?\u003c\/p\u003e\n\u003cp\u003eA: The panel functions as a passive interface termination board, routing field contact voltages directly without drawing backplane logic current.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all system and field excitation power sources prior to mounting or wiring the terminal panel assembly.\u003c\/li\u003e\n\u003cli\u003eMount the panel inside a dry, clean industrial enclosure, preserving clearance around wiring channels for heat dissipation.\u003c\/li\u003e\n\u003cli\u003eTorque field terminal connections according to local electrical codes for specified 5-250 VDC and 24-250 VAC operating limits.\u003c\/li\u003e\n\u003cli\u003eEarth ground the panel chassis ground stud to the central cabinet bus bar to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003ePractice ESD-safe handling procedures, including grounded wrist straps, during hardware installation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67851511136552,"sku":"900RTR-H001","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/900RTR-H001_Cocoai.png?v=1791447138","url":"https:\/\/www.powerdcs.com\/ar\/products\/honeywell-900rtr-h001-controledge-hc900-remote-terminal-panel","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}