Honeywell CC-TAIM01 51305959-175 Analog Input Module
Specifications
Manufacturer: Honeywell
Product No.: CC-TAIM01 51305959-175
Condition: 10 العناصر الموجودة في المخزون
Product Type: Analog Input Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 5000g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
The Honeywell CC-TAIM01 51305959-175, also cataloged as the CC-TAIM01 Analog Input Module, operates as a dedicated hardware component for millivolt signal acquisition and RTD resistance processing within Experion PKS Series C platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | CC-TAIM01 51305959-175 |
| Brand | Honeywell |
| Origin | USA |
| Operating Temp | -40 to +70 deg C |
| Power Consumption | 24 VDC IOTA bus supply |
| Module Type | Low Level Analog Input Multiplexer Card |
| Part Number | 51305959-175 |
| Sensor Support | Thermocouples (TC) and Resistance Temperature Detectors (RTD) |
| Environmental Protection | G3 conformal coating |
| Diagnostics | Configurable upscale or downscale sensor burnout detection |
Cold Junction Compensation & Channel-to-Channel Isolation
The CC-TAIM01 module utilizes dedicated Cold Junction Compensation (CJC) algorithms and reference junction hardware to maintain measurement accuracy across temperature-critical thermocouple channels. Integrated differential multiplexing circuits combined with high-order analog filtering isolate incoming millivolt-level signals from high-frequency electromagnetic noise. Channel-to-channel isolation barriers prevent ground loop currents from skewing low-amplitude signal paths, delivering stable temperature readings into the Experion PKS Control Execution Environment (CEE).
Frequently Asked Questions
Q: How does the CC-TAIM01 handle a broken or disconnected thermocouple sensor?
A: Each channel features configurable upscale or downscale burnout detection that automatically flags open-circuit conditions to the controller, preventing stale data from affecting control logic.
Q: Can different thermocouple types be wired to channels on the same CC-TAIM01 module?
A: Yes, channels are individually software-configurable for distinct thermocouple types or RTD curves, provided appropriate compensation wiring is landed at the terminal assembly.
Q: What environmental protections are built into the -175 hardware revision?
A: The -175 revision includes standard G3 conformal coating, protecting internal circuitry against airborne corrosives, moisture, and chemical vapors.
Field Installation Guidelines
- Mount the CC-TAIM01 vertically onto its designated Series C IOTA slot until the mechanical retention clips fully lock.
- Terminate thermocouple extension wires or RTD leads using shielded, twisted-pair cabling directly to the IOTA screw terminal block.
- Connect the cable shield drain wire to the cabinet single-point ground bar to minimize common-mode voltage interference.
- Verify that Cold Junction Compensation sensors on the terminal assembly are installed and isolated from direct cabinet thermal discharge.
كيفية الحصول على عرض أسعار
تتبع الطلب
شركات الشحن
سياسة وشروط الاسترداد
شروط الضمان
منتجات ذات صله
- يؤدي اختيار تحديد إلى تحديث كامل للصفحة.