{"product_id":"honeywell-cc-tdil01-51308386-175-digital-input-module","title":"Honeywell CC-TDIL01 51308386-175 Digital Input Module","description":"\u003cp\u003eConfigured for discrete signal acquisition and processing in Honeywell Experion PKS Series C platforms, the \u003cstrong\u003eHoneywell CC-TDIL01 51308386-175\u003c\/strong\u003e (\u003cstrong\u003eCC-TDIL01\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution. It interfaces 24 VDC field contacts, pushbuttons, and limit switches directly to the controller backplane with galvanic signal isolation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TDIL01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51308386-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 lbs (approx. 0.09 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.7 x 2.7 x 1.2 inches (119.4 x 68.6 x 30.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eOptical channel-to-channel and channel-to-system isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eI\/O Termination Assembly (IOTA) rack mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TDIL01 module features individual optocoupler-based isolation barriers across all input channels to prevent ground loops and common-mode voltage transients from propagating into the Series C backplane bus. The module incorporates active input debounce filtering to eliminate mechanical contact bounce noise on discrete field lines. Each channel continuously validates voltage state thresholds, mapping input levels below 5 VDC as logic zero and signals between 18 VDC and 30 VDC as logic high, maintaining high signal integrity across long field cabling runs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CC-TDIL01 module be hot-swapped while the Series C IOTA board is powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports live insertion and removal (hot-swapping) on an energized IOTA board without disturbing adjacent operational I\/O modules or corrupting backplane communication.\u003c\/p\u003e\n\u003cp\u003eQ: What action occurs if the field supply voltage drops below the minimum 18 VDC threshold?\u003c\/p\u003e\n\u003cp\u003eA: An input voltage drop below the 18 VDC operating limit causes the channel logic to register a false (OFF) state or generate a field power diagnostic fault, protecting the system from indeterminate logic transitions.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module require separate field supply power wiring directly to the module casing?\u003c\/p\u003e\n\u003cp\u003eA: No. All field wiring and 24 VDC power distribution route directly through the underlying IOTA terminal blocks. The CC-TDIL01 receives field power and backplane connection via multi-pin header connectors upon insertion into the IOTA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the target slot on the I\/O Termination Assembly (IOTA) is clean, free of debris, and aligned with the module card guides.\u003c\/li\u003e\n\u003cli\u003eAlign the multi-pin rear connectors of the CC-TDIL01 module with the matching header on the IOTA board.\u003c\/li\u003e\n\u003cli\u003ePress the module firmly into place until the retention mechanism fully engages to prevent vibration-induced loosening.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring leads are securely landed on the IOTA screw terminals using proper crimped ferrules, maintaining separation between low-voltage signal cabling and AC power conduits.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields to the dedicated ground bus on the IOTA structure. Ensure single-point grounding to prevent circulating ground currents.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52346303185192,"sku":"CC-TDIL01 51308386-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-TDIL0151308386-175.png?v=1788848140","url":"https:\/\/www.powerdcs.com\/ar\/products\/honeywell-cc-tdil01-51308386-175-digital-input-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}