Honeywell FS-CCE-232-02/L10 Communication Cable

Specifications

  • Manufacturer: Honeywell

  • Product No.: FS-CCE-232-02/L10

  • Condition: 10 العناصر الموجودة في المخزون

  • Product Type: Communication Cables

  • Payment:T/T, Western Union

  • Weight: 1100g

  • Shipping port: Xiamen

  • Warranty: 12 months

تفاصيل المنتج

وصف

The Honeywell FS-CCE-232-02/L10, also cataloged as the FS-CCE-232-02/L10 Communication Cable, operates as a dedicated hardware component for RS-232 serial data transmission within Honeywell Safety Manager systems.

Hardware Specifications

Parameter Specification
Model FS-CCE-232-02/L10
Brand Honeywell
Origin USA
Weight Approx. 1.10 kg
Dimensions 10.0 m (32.8 ft) cable length
Operating Temp -20 deg C to +70 deg C
Power Consumption Passive signal transmission assembly
Interface Standard RS-232 serial communication
Cable Length 10.0 m
Conductor Type Shielded multi-core twisted copper pairs
Connector Type Industrial sub-D / module plug connectors
System Compatibility Honeywell Safety Manager / FSC Controllers

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The FS-CCE-232-02/L10 cable utilizes high-coverage braided metallic shielding and foil wrapping to isolate high-speed serial data lines from external electromagnetic interference (EMI). By preventing serial switching noise from radiating onto adjacent cabinet backplanes, the cable protects the integrity of nearby analog I/O circuits. This preserves channel-to-channel isolation references and prevents signal distortion on field-side loops running 4-20 mA HART loop protocol communications.

Frequently Asked Questions

Q: What does the "L10" suffix represent in the FS-CCE-232-02/L10 part number?

A: The "L10" suffix designates the factory-manufactured overall cable length of 10.0 meters (32.8 ft).

Q: Is the FS-CCE-232-02/L10 cable designed for full-duplex RS-232 communication?

A: Yes, the cable incorporates dedicated transmit (TX), receive (RX), and handshake lines wired for standard full-duplex serial interface protocols.

Q: Can this communication cable be installed in the same wire duct as 230 VAC power lines?

A: No, low-voltage communication cabling must be physically separated from high-voltage AC cables to prevent inductive noise coupling and signal degradation.

Field Installation Guidelines

  • Verify that controller serial ports are powered down or isolated before seating or removing the cable connectors.
  • Tighten all connector thumbscrews and locking latches to ensure constant grounding contact and strain relief.
  • Maintain a minimum bend radius of at least 10 times the cable outer diameter during wire duct installation.
  • Connect shield drain wires directly to the designated enclosure earth bus bar at a single terminal point to prevent ground loops.

كيفية الحصول على عرض أسعار

تتبع الطلب

شركات الشحن

سياسة وشروط الاسترداد

شروط الضمان

منتجات ذات صله