Honeywell FS-PDC-MB24-2P Power Distribution Cable
Specifications
Manufacturer: Honeywell
Product No.: FS-PDC-MB24-2P
Condition: 10 العناصر الموجودة في المخزون
Product Type: Power Distribution Cables
Payment:T/T, Western Union
Weight: 420g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
The Honeywell FS-PDC-MB24-2P, also cataloged as the FS-PDC-MB24 Power Distribution Cable, operates as a dedicated hardware component for internal cabinet DC power distribution within Honeywell Safety Manager systems.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FS-PDC-MB24-2P |
| Brand | Honeywell |
| Origin | United States |
| Weight | 0.35 kg |
| Dimensions | 15.1 x 3 x 10 cm |
| Operating Temp | 0 deg C to +60 deg C |
| Power Consumption | Passive distribution assembly (24 VDC system bus) |
| Cable Assembly Type | Internal 2-pole Power Distribution Harness |
| Connector Type | Heavy-duty polarized industrial plug connectors |
| Shielding / Insulation | Flame-retardant industrial insulating sheath |
4-20 mA HART Loop Protocol and Channel-to-Channel Isolation
The FS-PDC-MB24-2P cable assembly supplies low-noise 24 VDC power directly to field bus interfaces and analog channel cards. Maintaining high channel-to-channel isolation on associated input circuits prevents system-wide ground loops and voltage dips during high-load switching events. This stable power rail preserves signal transmission integrity across sensitive process instrument loops operating on the 4-20 mA HART loop protocol.
Frequently Asked Questions
Q: Can the FS-PDC-MB24-2P power harness be disconnected while the system backplane is energized?
A: Live disconnection under load must be avoided; ensure the associated breaker or power distribution module is de-energized prior to removing connector contacts.
Q: What is the primary function of the 2-pole connector configuration?
A: The keyed 2-pole keyed connection carries direct positive (+24 VDC) and return (0 VDC) power connections while preventing reverse-polarity insertion.
Q: What environmental conditions apply to the storage and installation of this cable module?
A: Standard operating limits range from 0 deg C to +60 deg C in non-condensing control cabinet enclosures.
Field Installation Guidelines
- Inspect connector pins and housing retaining latches for mechanical integrity before insertion.
- Align connector keying notches precisely with mating sockets on the power distribution board to prevent physical strain or pin damage.
- Ensure terminal locking screws or retaining clips are fully engaged to prevent accidental looseness caused by panel vibration.
- Route power distribution harnesses clear of sharp chassis edges and maintain separation from AC voltage wiring.