Honeywell FS-PSU-240516 Power Supply Module
Specifications
Manufacturer: Honeywell
Product No.: FS-PSU-240516
Condition: 10 العناصر الموجودة في المخزون
Product Type: Power Supply Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 850g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
The Honeywell FS-PSU-240516, also cataloged as the FS-PSU-240516 Power Supply Unit, operates as a dedicated hardware component for regulated DC power delivery within Honeywell process control and safety platforms. It converts wide-range AC or DC field inputs to stabilized 24 VDC output power to energize controller backplanes and field instrumentation loops.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FS-PSU-240516 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.85 kg |
| Dimensions | 21.1 cm x 3.52 cm x 17.6 cm |
| Operating Temp | -20 to +70 deg C |
| Power Consumption | Passive dissipation loss (Efficiency > 96%) |
| Input Voltage Range | 85-265 VAC or 100-370 VDC |
| Output Voltage | 24 VDC |
| Output Current | 16 A |
| Ingress Protection | IP20 |
| Storage Temp | -40 to +85 deg C |
| Relative Humidity | 10-95%, non-condensing |
Process Control & DCS Signal Power Delivery Characteristics
The FS-PSU-240516 power supply module incorporates channel-to-channel isolation and low-ripple output regulation to preserve signal accuracy across connected analog circuits. Delivering a continuous 16 A output at 24 VDC, the unit supplies clean DC potential to 4-20 mA HART loop protocol transmitters and I/O bus interface modules. High conversion efficiency exceeding 96% reduces internal heat generation within enclosure racks, maintaining voltage stability across variable input power conditions.
Frequently Asked Questions
Q: What input power sources can be wired to the FS-PSU-240516 module terminals?
A: The input stage accepts wide-range supplies operating from 85-265 VAC or 100-370 VDC without physical jumper selection.
Q: How does the unit maintain thermal performance within enclosed cabinets?
A: Operating at >96% conversion efficiency minimizes internal heat dissipation, supporting stable operational delivery up to +70 deg C ambient conditions.
Q: Is hot-swapping supported when replacing a faulty power supply module in a redundant rack?
A: Yes, in parallel redundant configurations, a faulty module can be extracted and replaced while the online partner maintains continuous 24 VDC bus potential to field loops.
Field Installation Guidelines
- Mounting & Airflow Clearance: Mount the module vertically on standard panel rails inside IP20-rated enclosures. Maintain a minimum vertical clearance of 50 mm above and below the housing to facilitate natural convection cooling.
- Input Wiring & Fusing: Connect primary supply lines using wire cross-sections rated for the maximum input current. Install external fast-acting fuses on the line side according to local cabinet protection schematics.
- Grounding Connection: Terminate the Protective Earth (PE) drain connection directly to the enclosure main earthing bar using a low-impedance ground strap before applying line power.
- Output Wiring Segregation: Route 24 VDC output power conductors in dedicated low-voltage wiring ducts, maintaining separation from AC supply lines to prevent electromagnetic coupling.