Honeywell FS-SICC-0001/L8 System Interconnection Cable
Specifications
Manufacturer: Honeywell
Product No.: FS-SICC-0001/L8
Condition: 10 العناصر الموجودة في المخزون
Product Type: Cable Assemblies
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
The Honeywell FS-SICC-0001/L8, also cataloged as the FS-SICC-0001 System Interconnection Cable, operates as a dedicated hardware component for multi-core signal routing and field termination assembly (FTA) interconnection within Honeywell Safety Manager and FSC systems.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FS-SICC-0001/L8 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.35 kg |
| Dimensions | 8 m length (Nominal cable outer diameter approx. 9.93 mm) |
| Operating Temp | -20 deg C to +85 deg C |
| Power Consumption | Passive interconnect assembly (Zero internal power draw) |
| Cable Type | Multi-core system interconnection cable |
| Voltage Rating | 300 V |
| Impedance Rating | 120 ohm nominal characteristic impedance |
| Conductor Material | High-quality copper with thermoplastic insulation |
| Shielding | Integrated EMI shielding |
| System Compatibility | Honeywell Safety Manager / FSC Systems |
4-20 mA HART Loop Protocol and Channel-to-Channel Isolation
The multi-core cable structure uses thermoplastic-insulated copper conductors surrounded by an overall EMI shield to maintain channel-to-channel isolation principles across parallel signal lines. Controlled 120 ohm nominal impedance minimizes transmission line reflections during high-speed digital communications, while physical dielectric isolation prevents high-frequency noise from coupling onto analog 4-20 mA HART loop protocol lines or discrete safety shutdown circuits.
Frequently Asked Questions
Q: What primary cabinet hardware interfaces are connected by the FS-SICC-0001/L8 cable assembly?
A: The cable interconnects Safety Manager system modules and chassis I/O slots to remote Field Termination Assemblies (FTAs).
Q: Can the cable assembly be disconnected while the connected I/O rack is energized?
A: Unplugging the cable severs active I/O communication between the controller chassis and the connected FTA; field signals or safety loops tied to the cable must be bypassed prior to physical removal.
Q: How does the overall EMI shield impact noise rejection in high-interference environments?
A: The continuous metallic shielding blocks external electromagnetic and radio-frequency interference from inducing noise voltages on low-level analog and digital field telemetry circuits.
Field Installation Guidelines
- Route the 8 meter cable assembly through dedicated low-voltage cable trays or enclosure wireways, keeping clear of AC power lines and VFD output conductors.
- Observe a minimum static bending radius along the cable run to avoid pinching internal copper conductors or tearing the outer EMI shield mesh.
- Fully engage factory-terminated pin headers into mating chassis or FTA connectors and tighten retention hardware to ensure vibration-proof low-resistance contact.
- Connect the cable shield drain wire directly to the cabinet protective earth (PE) ground bus bar at a single termination point to prevent circulating ground potential loops.