Honeywell GCP-32AN M 1A Circuit Breaker
Specifications
Manufacturer: Honeywell
Product No.: GCP-32AN M 1A
Condition: 10 العناصر الموجودة في المخزون
Product Type: Circuit Breakers
Product Origin: USA
Payment:T/T, Western Union
Weight: 120g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
The GCP-32AN M 1A (also cataloged as the GCP-32AN) is a precision circuit breaker manufactured by Honeywell to provide overcurrent protection and branch circuit isolation within control panels and power distribution networks. Designed for low-current loops, this breaker monitors continuous current and executes thermal-magnetic tripping when levels exceed its 1 A rating. It isolates downstream field devices and delicate I/O modules from short-circuit transients and sustained overloads.
Trip Mechanism and Performance
The unit utilizes a calibrated thermal-magnetic sensing element that reacts rapidly to overcurrent events while suppressing switching arc transients. Internal contact decoupling prevents ground potential migration during trip conditions, ensuring that faults on individual branch loops do not propagate back to primary system power buses or corrupt neighboring signal channels.
Field Installation Guidelines
- Snap the breaker onto an unpainted section of a standard 35 mm DIN rail, ensuring the grounding clip achieves positive metallic contact with the cabinet ground reference.
- Strip conductor ends to the specified length and torque the terminal screw clamps to prevent loose connection resistance and localized heating.
- Maintain physical separation between incoming power supply feeds and low-voltage field signal wiring to prevent electromagnetic coupling.
- Verify that total connected load current on the protected branch loop does not exceed the nominal 1 A rating under normal operating temperatures.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | GCP-32AN M 1A |
| Brand | Honeywell |
| Rated Current | 1 A |
| Trip Mechanism | Thermal-Magnetic |
| Mounting Type | Standard 35 mm DIN rail |
| Power Consumption | Passive (Low internal resistance) |
| Operating Temp | -20 deg C to +60 deg C |
| Dimensions | 75 mm x 18 mm x 80 mm |
| Weight | 0.12 kg |
| Country of Origin | United States |
Frequently Asked Questions
Q: Does the GCP-32AN M 1A support auxiliary contact signaling for remote fault detection?
A: The breaker interface includes mechanical indicator positions for local visual status, and auxiliary fault signal contacts can be side-mounted to feed trip status logic directly into DCS digital input channels.
Q: Can this circuit breaker be reset immediately following a high-current short-circuit trip?
A: Mechanical reset is permitted after a brief cooling period; however, the downstream loop must be inspected for persistent short circuits prior to re-energizing to avoid thermal stress on the internal bimetallic strip.