{"product_id":"honeywell-gcp-32an-m-1a-circuit-breaker","title":"Honeywell GCP-32AN M 1A Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eGCP-32AN M 1A\u003c\/strong\u003e (also cataloged as the GCP-32AN) is a precision circuit breaker manufactured by Honeywell to provide overcurrent protection and branch circuit isolation within control panels and power distribution networks. Designed for low-current loops, this breaker monitors continuous current and executes thermal-magnetic tripping when levels exceed its 1 A rating. It isolates downstream field devices and delicate I\/O modules from short-circuit transients and sustained overloads.\u003c\/p\u003e\n\u003ch3\u003eTrip Mechanism and Performance\u003c\/h3\u003e\n\u003cp\u003eThe unit utilizes a calibrated thermal-magnetic sensing element that reacts rapidly to overcurrent events while suppressing switching arc transients. Internal contact decoupling prevents ground potential migration during trip conditions, ensuring that faults on individual branch loops do not propagate back to primary system power buses or corrupt neighboring signal channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the breaker onto an unpainted section of a standard 35 mm DIN rail, ensuring the grounding clip achieves positive metallic contact with the cabinet ground reference.\u003c\/li\u003e\n\u003cli\u003eStrip conductor ends to the specified length and torque the terminal screw clamps to prevent loose connection resistance and localized heating.\u003c\/li\u003e\n\u003cli\u003eMaintain physical separation between incoming power supply feeds and low-voltage field signal wiring to prevent electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eVerify that total connected load current on the protected branch loop does not exceed the nominal 1 A rating under normal operating temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGCP-32AN M 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Mechanism\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eStandard 35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Low internal resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e75 mm x 18 mm x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the GCP-32AN M 1A support auxiliary contact signaling for remote fault detection?\u003c\/p\u003e\n\u003cp\u003eA: The breaker interface includes mechanical indicator positions for local visual status, and auxiliary fault signal contacts can be side-mounted to feed trip status logic directly into DCS digital input channels.\u003c\/p\u003e\n\u003cp\u003eQ: Can this circuit breaker be reset immediately following a high-current short-circuit trip?\u003c\/p\u003e\n\u003cp\u003eA: Mechanical reset is permitted after a brief cooling period; however, the downstream loop must be inspected for persistent short circuits prior to re-energizing to avoid thermal stress on the internal bimetallic strip.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68075548836136,"sku":"GCP-32AN M 1A","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/GCP-32AM1A.png?v=1793609318","url":"https:\/\/www.powerdcs.com\/ar\/products\/honeywell-gcp-32an-m-1a-circuit-breaker","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}