Honeywell MC-TDOR12 51309148-175 Digital Relay Output Module

Specifications

  • Manufacturer: Honeywell

  • Product No.: MC-TDOR12 51309148-175

  • Condition: 10 العناصر الموجودة في المخزون

  • Product Type: Digital Output Modules

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 820g

  • Shipping port: Xiamen

  • Warranty: 12 months

تفاصيل المنتج

وصف

Configured for high-power field switching in Honeywell Distributed Control System networks, the Honeywell 51309148-175 (MC-TDOR12 Digital Relay Output) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model MC-TDOR12 51309148-175
Brand Honeywell
Origin USA
Weight 0.82 kg
Dimensions 46.1 cm x 12.0 cm x 5.5 cm (Size B / 12 inches)
Operating Temp 0 to 60 deg C
Power Consumption Backplane-supplied relay coil drive
Output Type Electromechanical Relay (Non-Redundant)
Channel Count 16 Channels
Voltage Rating 120 VAC / 125 VDC
Response Time < 10 ms
Terminal Interface Compression terminals

Fieldbus Communication & Channel Isolation

The MC-TDOR12 Field Termination Assembly isolates digital I/O processing logic from high-voltage field actuators using physical dry-contact switching. Operating within standard 4-20 mA HART loop protocol cabinet topologies and DCS I/O links, the board delivers channel-to-channel isolation across all 16 electromechanical relay paths. Integrated surge protection on each contact circuit suppresses switching transients, shielding central control buses from field-side voltage spikes and ground potential shifts.

Frequently Asked Questions

Q: What is the maximum response switching latency for the internal relay contacts?

A: The onboard electromechanical relays execute contact transition in less than 10 ms, supporting high-speed safety interlock and process output sequences.

Q: How does the MC-TDOR12 differ from standard low-voltage digital output cards?

A: Standard digital output modules drive low-current 24 VDC logic signals, whereas the MC-TDOR12 uses electromechanical relay contacts to switch higher AC/DC load voltages up to 120 VAC or 125 VDC.

Q: Can inductive field loads be connected directly to the output terminals?

A: Yes, the contacts handle inductive loads within the rated voltage limits; supplementary external surge suppressors may be placed across field coils to extend physical relay contact service life.

Field Installation Guidelines

  1. Disconnect backplane power and field load supplies prior to seating or replacing the assembly in the marshalling rack.
  2. Strip field conductor insulation according to standard compression terminal specifications to maintain torque retention and prevent short-circuit faults between adjacent channels.
  3. Ensure the cabinet earth ground cable is fastened to the designated grounding lug to maintain protective suppression barriers.