Honeywell MU-GAIH92 Analog Input Module
Specifications
Manufacturer: Honeywell
Product No.: MU-GAIH92
Condition: 10 العناصر الموجودة في المخزون
Product Type: Analog Input Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
Configured for high-accuracy signal acquisition in Honeywell DCS platforms, the Honeywell MU-GAIH92 (MU-GAIH92 Analog Input Module) provides direct physical/electrical execution. It processes standard 4 to 20 mA DC signals from field-mounted transmitters, executing 16-bit A/D conversion across 16 differential input channels to stream digitized process variables into central controller logic.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | MU-GAIH92 |
| Brand | Honeywell |
| Origin | USA |
| Operating Temp | 0 to 70 deg C |
| Power Consumption | 5 W |
| Input Channels | 16 Differential Channels |
| Input Signal | 4 to 20 mA DC |
| Resolution | 16-bit |
| Input Impedance | 250 Ohms (typical) |
| Common Mode Rejection | > 70 dB at 50/60 Hz |
| HART Protocol | HART 5, 6, 7 |
4-20 mA HART Loop Protocol and Channel-to-Channel Isolation
The MU-GAIH92 integrates 16 differential channels with greater than 70 dB common-mode noise suppression at 50/60 Hz to maintain channel-to-channel isolation across shared field wiring ducts. Equipped with an internal 250 Ohm loop termination impedance, the module supports bidirectional digital telemetry overlay via 4-20 mA HART loop protocol standards (HART 5, 6, and 7). This internal interface enables real-time field device configuration and diagnostic pass-through while isolating internal processing logic from common-mode electrical transients.
Frequently Asked Questions
Q: What is the power consumption draw of the MU-GAIH92 module during operation?
A: The module exhibits a maximum power consumption rating of 5 W under standard 16-channel active operating conditions.
Q: Can the MU-GAIH92 communicate with different revisions of HART transmitters on the same channel rack?
A: Yes, the onboard hardware interface natively supports HART protocols 5, 6, and 7 for dynamic digital data extraction alongside the 4 to 20 mA analog signal.
Field Installation Guidelines
- Disconnect control cabinet power before inserting or extracting the module from the chassis frame.
- Utilize ESD-safe wrist straps and grounding equipment during physical handling of the module assembly.
- Route field inputs using shielded twisted-pair cabling to minimize electromagnetic interference (EMI).
- Terminate signal cable shields to the master cabinet ground bus at a single reference point to preserve channel isolation.
- Verify cabinet ventilation pathways are unobstructed to maintain internal thermal levels within the 0 to 70 deg C operating window.
كيفية الحصول على عرض أسعار