Honeywell MU-KFTA10 51201420-010 FTA Cable

Specifications

  • Manufacturer: Honeywell

  • Product No.: MU-KFTA10

  • Condition: 10 العناصر الموجودة في المخزون

  • Product Type: I/O Cables

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 600g

  • Shipping port: Xiamen

  • Warranty: 12 months

تفاصيل المنتج

وصف

Configured for low-loss signal transmission and cabinet-to-field interconnectivity in Honeywell TDC 3000 systems, the Honeywell MU-KFTA10 (51201420-010 FTA Cable) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model MU-KFTA10
Part Number 51201420-010
Brand Honeywell
Origin USA
Dimensions 10 meters overall cable length
Operating Temp -20 to 70 deg C
Power Consumption Passive interconnect assembly
Cable Type Field Termination Assembly (FTA) Cable
Signal Compatibility Discrete and Analog I/O Signals
System Platform Honeywell Process Manager / High Performance Process Manager (HPM)

Channel-to-Channel Isolation & Loop Protocol

The cable assembly incorporates multi-pair twisted wires with individualized foil shielding to preserve channel-to-channel isolation parameters across extended run distances. Designed to transport process automation signals including 4-20 mA HART loop protocol streams, the physical pin layout prevents capacitive coupling and crosstalk between adjacent channels during high-density signal multiplexing operations.

Frequently Asked Questions

Q: Does the 10-meter length of the MU-KFTA10 cable introduce signal attenuation on 4-20 mA HART loops?

A: No, current-loop signals (4-20 mA) maintain continuous loop accuracy across 10 meters, provided the total loop resistance remains within the drive capacity of the connected I/O module.

Q: What physical bend radius must be maintained during installation inside dense control cabinets?

A: Standard installation practices mandate maintaining a minimum dynamic bend radius of 10 times the outer cable diameter to avoid conductor fatigue and internal shield degradation.

Field Installation Guidelines

  • Ensure system power is disconnected or appropriate hot-swap safety protocols are followed prior to connecting or disconnecting the cable connectors.
  • Route the FTA cable through dedicated low-voltage wiring troughs, separated from high-voltage AC power distribution lines by a minimum distance of 300 mm.
  • Verify full mechanical latching or screw engagement on the multi-pin connectors at both the I/O panel and the field termination assembly.
  • Earth the overall shield drain wire at a single designated ground bar to prevent ground loop currents from corrupting analog instrumentation readings.
  • Avoid applying axial tension or exceeding the minimum static bend radius during cable pull through cable trays or conduit networks.