Honeywell MU-KFTA10 51201420-010 FTA Cable
Specifications
Manufacturer: Honeywell
Product No.: MU-KFTA10
Condition: 10 العناصر الموجودة في المخزون
Product Type: I/O Cables
Product Origin: USA
Payment:T/T, Western Union
Weight: 600g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
Configured for low-loss signal transmission and cabinet-to-field interconnectivity in Honeywell TDC 3000 systems, the Honeywell MU-KFTA10 (51201420-010 FTA Cable) provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | MU-KFTA10 |
| Part Number | 51201420-010 |
| Brand | Honeywell |
| Origin | USA |
| Dimensions | 10 meters overall cable length |
| Operating Temp | -20 to 70 deg C |
| Power Consumption | Passive interconnect assembly |
| Cable Type | Field Termination Assembly (FTA) Cable |
| Signal Compatibility | Discrete and Analog I/O Signals |
| System Platform | Honeywell Process Manager / High Performance Process Manager (HPM) |
Channel-to-Channel Isolation & Loop Protocol
The cable assembly incorporates multi-pair twisted wires with individualized foil shielding to preserve channel-to-channel isolation parameters across extended run distances. Designed to transport process automation signals including 4-20 mA HART loop protocol streams, the physical pin layout prevents capacitive coupling and crosstalk between adjacent channels during high-density signal multiplexing operations.
Frequently Asked Questions
Q: Does the 10-meter length of the MU-KFTA10 cable introduce signal attenuation on 4-20 mA HART loops?
A: No, current-loop signals (4-20 mA) maintain continuous loop accuracy across 10 meters, provided the total loop resistance remains within the drive capacity of the connected I/O module.
Q: What physical bend radius must be maintained during installation inside dense control cabinets?
A: Standard installation practices mandate maintaining a minimum dynamic bend radius of 10 times the outer cable diameter to avoid conductor fatigue and internal shield degradation.
Field Installation Guidelines
- Ensure system power is disconnected or appropriate hot-swap safety protocols are followed prior to connecting or disconnecting the cable connectors.
- Route the FTA cable through dedicated low-voltage wiring troughs, separated from high-voltage AC power distribution lines by a minimum distance of 300 mm.
- Verify full mechanical latching or screw engagement on the multi-pin connectors at both the I/O panel and the field termination assembly.
- Earth the overall shield drain wire at a single designated ground bar to prevent ground loop currents from corrupting analog instrumentation readings.
- Avoid applying axial tension or exceeding the minimum static bend radius during cable pull through cable trays or conduit networks.
كيفية الحصول على عرض أسعار
تتبع الطلب
شركات الشحن
سياسة وشروط الاسترداد
شروط الضمان
منتجات ذات صله
- يؤدي اختيار تحديد إلى تحديث كامل للصفحة.