Honeywell MU-KFTA30 Field Termination Assembly Cable
Specifications
Manufacturer: Honeywell
Product No.: MU-KFTA30
Condition: 10 العناصر الموجودة في المخزون
Product Type: Field Termination Assembly Cables
Product Origin: USA
Payment:T/T, Western Union
Weight: 3500g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
Configured for multi-channel field signal interconnection and data routing in Honeywell TDC 3000 and TPS platforms, the Honeywell 51197595-300 (MU-KFTA30 Field Termination Assembly Cable) provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | MU-KFTA30 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 3.50 kg |
| Dimensions | 400 mm x 400 mm x 80 mm |
| Operating Temp | -10 to +60 deg C |
| Power Consumption | Passive interconnect assembly |
| Part Number | 51197595-300 (or 51201420-030) |
| Cable Length | 30 m (98.4 ft) |
| Nominal Voltage | 24 VDC |
| Interface Support | RS485 / Analog Signal Support |
| Connector Type | Factory pre-terminated industrial connectors |
Channel-to-Channel Isolation & 4-20 mA Loop Integration
The 30-meter cable assembly provides structured multi-conductor routing between field termination boards and process I/O cards. Designed to operate parallel to 4-20 mA HART loop protocol architectures and RS485 communication lines, the continuous internal shielding structure attenuates ambient high-frequency noise. Channel-to-channel isolation limits mutual capacitance coupling and mitigates ground loop potential across extended analog signal runs.
Frequently Asked Questions
Q: Does the MU-KFTA30 cable assembly consume active power from the controller rack?
A: No. The MU-KFTA30 functions as a passive physical interconnect assembly carrying 24 VDC supply lines and signal pathways without internal power consumption.
Q: Can the 30-meter cable length be cut and re-terminated in the field?
A: Field cutting or hand-crimping of pre-terminated connectors is not recommended, as altering factory soldered pin connections disrupts line impedance and shield continuity.
Q: Is propagation delay affected over the full 30-meter cable run?
A: System timing and signal attenuation parameters are factory-validated for the 30-meter physical length, keeping propagation delays within standard DCS bus tolerances.
Field Installation Guidelines
- Align plug orientation keys carefully prior to seating connectors into field termination boards or I/O modules to prevent pin damage.
- Maintain recommended minimum bend radii along the entire cable route to preserve conductor geometry and shielding layer integrity.
- Lay signal extension cables in low-voltage instrument trays separate from high-voltage AC lines and variable frequency drive outputs.
- Terminate shield drain wires directly to the central system instrumentation grounding bar per factory engineering standards.
- Secure mechanical strain relief clamps at panel entry points to prevent physical tension on connector pins.