{"product_id":"honeywell-tc-idj161-experion-pks-high-density-digital-input-module","title":"Honeywell TC-IDJ161 Experion PKS High Density Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-IDJ161 frn 2.1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-IDJ161\u003c\/strong\u003e Digital Input Modules, operates as a dedicated hardware component for isolated discrete signal monitoring within Experion PKS C200\/C300 process controllers and chassis assemblies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-IDJ161 (Firmware Revision: FRN 2.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C housing environmental envelope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane logic draw based on active channel states\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eIsolated DC digital input assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 discrete input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eGroup and channel-to-channel isolation architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eDigital Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe TC-IDJ161 module executes signal filtering and optical channel-to-channel isolation across its 16 discrete input points. Galvanic isolation circuits disconnect high-voltage field surges and ground potential differences from reaching the internal controller backplane logic. The integrated filtering networks reduce high-frequency electrical noise, debouncing field switch transitions and dry contact closures before updating input image registers in the main controller process memory.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does replacing a TC-IDJ161 module require powering down the entire chassis backplane?\u003c\/p\u003e\n\u003cp\u003eA: Module removal under power (hot-swapping) is supported if permitted by cabinet safety classifications and system operational procedures.\u003c\/p\u003e\n\u003cp\u003eQ: What impact does Firmware Revision FRN 2.1 have on hardware compatibility?\u003c\/p\u003e\n\u003cp\u003eA: FRN 2.1 establishes specific firmware flash compatibility with corresponding C200 or C300 controller software releases and backplane communication protocols.\u003c\/p\u003e\n\u003cp\u003eQ: How is field wiring terminated to the TC-IDJ161 digital input channels?\u003c\/p\u003e\n\u003cp\u003eA: Field conductors connect via removable terminal blocks (RTBs) keyed specifically to prevent improper high-voltage module insertion.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInsert the TC-IDJ161 module into the designated slot on the chassis rack until the upper and lower housing latches click into place.\u003c\/li\u003e\n\u003cli\u003eVerify that the removable terminal block keying alignment matches the pin arrangement of the TC-IDJ161 hardware.\u003c\/li\u003e\n\u003cli\u003eRoute field input wiring through cabinet wire ducts, keeping DC signal lines physically separated from high-voltage AC power lines.\u003c\/li\u003e\n\u003cli\u003eSecure all field drain wires and shield connections directly to the local earth grounding bus.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52364649824552,"sku":"TC-IDJ161","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/TC-IDJ1612_Cocoai.png?v=1789025258","url":"https:\/\/www.powerdcs.com\/ar\/products\/honeywell-tc-idj161-experion-pks-high-density-digital-input-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}