{"product_id":"honeywell-tc-odk161-ac-digital-output-module","title":"Honeywell TC-ODK161 AC Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-ODK161\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-ODK161\u003c\/strong\u003e AC Digital Output Module, operates as a dedicated hardware component for switching high-voltage AC field discrete devices across Honeywell DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-ODK161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Rack Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem Backplane Driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e120\/220 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e16 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e2 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevision Level\u003c\/td\u003e\n\u003ctd\u003eRev G0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe TC-ODK161 incorporates internal optical isolation barriers between backplane logic circuitry and field-side switching elements. Channel-to-channel isolation suppresses inductive kickback transients and ground loops originating from solenoid valves, motor starters, or AC actuators. This electrical isolation prevents field-side AC interference from propagating to adjacent analog processing racks carrying sensitive 4-20 mA HART loop communication networks or precision measurement logic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum AC load current capacity per output point on the TC-ODK161?\u003c\/p\u003e\n\u003cp\u003eA: Each individual output point on the TC-ODK161 module supports a maximum continuous load current of 2 A at 120\/220 VAC (50\/60 Hz).\u003c\/p\u003e\n\u003cp\u003eQ: Does inserting or removing the TC-ODK161 require shutting down system backplane power?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping must strictly conform to system chassis guidelines; verify that field-side 120\/220 VAC power distribution circuits are isolated before removing or inserting the module to prevent electrical arcing across backplane pins.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate all external 120\/220 VAC field power sources prior to connecting or disconnecting wiring harnesses from the terminal block assembly.\u003c\/li\u003e\n\u003cli\u003eMaintain clear physical separation between AC high-voltage output wiring and low-voltage analog signal cables to prevent inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003eSecure the module chassis firmly into the backplane slot, ensuring positive engagement of retaining clips to verify proper earth ground continuity.\u003c\/li\u003e\n\u003cli\u003eConnect field cable shields to the dedicated cabinet single-point ground bar to minimize electromagnetic interference across control channels.\u003c\/li\u003e\n\u003cli\u003eVerify total current load per output group to ensure thermal limits within the control enclosure are not exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52368480698664,"sku":"TC-ODK161","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/TC-ODJ161_9b547cef-f9d8-496a-8bc0-8d61a03855d2.png?v=1789112413","url":"https:\/\/www.powerdcs.com\/ar\/products\/honeywell-tc-odk161-ac-digital-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}