{"product_id":"honeywell-tk-0av061-experion-pks-analog-output-module","title":"Honeywell TK-0AV061 Experion PKS Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell TK-0AV061\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTK-0AV061\u003c\/strong\u003e Analog Output Modules, operates as a dedicated hardware component for isolated analog control signal generation within Experion PKS C200\/C300 controller chassis platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-0AV061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.5 cm x 14.0 cm x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C housing environmental envelope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 mA at 24 VDC external power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e6 isolated analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e20 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% FS (full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Cold Junction Compensation (CJC) Coexistence\u003c\/h3\u003e\n\u003cp\u003eThe TK-0AV061 module converts internal controller logic values into 6 galvanically isolated 0 to 10 VDC analog outputs with 12-bit resolution and a 2 ms execution update rate. Channel-to-channel isolation prevents ground loop current formation across field loops, maintaining signal integrity when operating alongside adjacent 4-20 mA HART loop protocol wiring or low-voltage thermocouple assemblies relying on cold junction compensation (CJC). The physical isolation structure prevents field transients on one channel from causing cross-talk or voltage deviations on neighboring signal lines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does replacing a TK-0AV061 analog output module require cycling power to the system chassis?\u003c\/p\u003e\n\u003cp\u003eA: Module removal under power (hot-swapping) is supported on compatible backplanes provided local cabinet safety procedures and hazardous location requirements are met.\u003c\/p\u003e\n\u003cp\u003eQ: How does channel-to-channel isolation protect the analog output circuits on the TK-0AV061?\u003c\/p\u003e\n\u003cp\u003eA: Internal galvanic barriers isolate each output channel from backplane logic and adjacent field lines, suppressing ground potential differences up to the module isolation rating.\u003c\/p\u003e\n\u003cp\u003eQ: What power source drives the output channels of the TK-0AV061 module?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on a nominal 24 VDC auxiliary power supply input, drawing 100 mA under full 6-channel operational load.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAlign the TK-0AV061 module circuit board guides with the target slot on the chassis rack and push firmly until the locking levers engage.\u003c\/li\u003e\n\u003cli\u003eRoute 0 to 10 VDC signal wiring using twisted-pair shielded cables to suppress external high-frequency electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eGround signal cable shield drain conductors to the designated cabinet ground bus bar at a single point only.\u003c\/li\u003e\n\u003cli\u003eVerify correct terminal screw torque and wiring polarity before energizing the 24 VDC field power supply.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52364655788328,"sku":"TK-OAV061","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/TK-OAV061_Cocoai_4bee3bfa-5357-4b51-8a8b-ae18f9fdd6c8.png?v=1789026474","url":"https:\/\/www.powerdcs.com\/ar\/products\/honeywell-tk-0av061-experion-pks-analog-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}