{"product_id":"mc-hpfx02-51304362-175-honeywell-15-slot-card-file-assembly","title":"MC-HPFX02 51304362-175 Honeywell 15-Slot Card File Assembly","description":"\u003cp\u003eConfigured for multi-module backplane bus power distribution and I\/O card housing in Experion PKS and TPS DCS platforms, the \u003cstrong\u003eHoneywell 51304362-175\u003c\/strong\u003e (\u003cstrong\u003eMC-HPFX02\u003c\/strong\u003e 15-Slot Card File Assembly) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-HPFX02 51304362-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e31.3 x 27.8 x 3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive backplane assembly (powered via system 24 VDC bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd\u003e15 I\/O and controller module slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eHoneywell analog, digital, and specialty I\/O cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eSupports redundant power supply routing and dual-I\/O links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe MC-HPFX02 card file assembly establishes backplane power distribution and signal routing across 15 hardware slots, connecting analog, digital, and specialty I\/O modules to system controllers. Supporting 4-20 mA HART loop protocol architectures, the backplane structure maintains physical channel-to-channel isolation between adjacent module slots, suppressing common-mode bus noise and ground potential shifts across redundant controller and power supply configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the MC-HPFX02 backplane accommodate redundant power supplies?\u003c\/p\u003e\n\u003cp\u003eA: The internal bus structure incorporates dual power input paths that accept independent 24 VDC feeds, maintaining card file operation if one power module drops offline.\u003c\/p\u003e\n\u003cp\u003eQ: What module types can be installed into the 15 available slots on the MC-HPFX02 assembly?\u003c\/p\u003e\n\u003cp\u003eA: The card file houses Honeywell analog input\/output, digital I\/O, pulse input, and dedicated serial communication cards compatible with TPS and Experion PKS platforms.\u003c\/p\u003e\n\u003cp\u003eQ: Can modules be inserted into the card file while the assembly is energized?\u003c\/p\u003e\n\u003cp\u003eA: Module replacement must adhere to Honeywell live-insertion guidelines for the specific controller platform to prevent transient power surges on the internal bus lines.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the MC-HPFX02 card file assembly securely onto the cabinet frame using panel screws, torquing fasteners to 1.5 Nm to maintain frame grounding.\u003c\/li\u003e\n\u003cli\u003eRoute primary and redundant 24 VDC power bus cables to the backplane input terminals, verifying correct polarity before applying power.\u003c\/li\u003e\n\u003cli\u003eConnect the main frame earthing strap directly to the cabinet ground bar using heavy-gauge copper grounding wire to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eVerify that module guide rails are free of debris and insert I\/O cards firmly until retaining latches click into place.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52393147564328,"sku":"MC-HPFX02","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/MC-HPFX02.jpg?v=1789550588","url":"https:\/\/www.powerdcs.com\/ar\/products\/mc-hpfx02-51304362-175-honeywell-15-slot-card-file-assembly","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}