Manufacturer: Honeywell
Product No.: MC-TAIH52 51304337-250
Condition: 10 العناصر الموجودة في المخزون
Product Type: Analog Input Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
The Honeywell MC-TAIH52 51304337-250, also cataloged as the MC-TAIH52 High Level Analog Input Module, operates as a dedicated hardware component for redundant high-level analog data acquisition within industrial process control platforms. This module conditions discrete continuous signals across 32 analog input channels from field transmitters and sensors. Operating within a 15 VDC to 30 VDC supply envelope, the assembly executes fault-tolerant signal conversion to prevent process disruptions during single-channel or loop perturbations.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | MC-TAIH52 (51304337-250) |
| Brand | Honeywell |
| Origin | USA / Global Manufacturing |
| Weight | 0.5 kg |
| Dimensions | 13.7 cm x 5.1 cm x 15.1 cm |
| Operating Temp | -40 to +85 deg C |
| Power Consumption | Less than 5 mA per channel |
| Product Type | Redundant High-Level Analog Input Module |
| Input Channels | 32 Analog Input Channels |
| Input Voltage Range | 15 VDC to 30 VDC |
| Power Supply Voltage | 15 VDC to 30 VDC |
| Communication Protocol | Modbus RTU |
DCS Process Control & Channel Isolation
The MC-TAIH52 module interfaces directly with process instrumentation, utilizing a 4-20 mA HART loop protocol framework and standard high-level voltage inputs to digitize critical process variables. Integrated channel-to-channel isolation safeguards the internal control bus against field-side voltage spikes, preventing common-mode noise propagation across the 32-channel multiplexing hardware.
By enforcing strict current limits under 5 mA per channel, the hardware limits internal power dissipation. This low power consumption enables high-density installation in marshalling cabinets while maintaining stable signal processing characteristics across an extended operating range of -40 to +85 deg C.
Frequently Asked Questions
Q: What is the maximum current draw per input channel on the MC-TAIH52 card?
A: Current consumption is restricted to less than 5 mA per channel under standard operating conditions.
Q: Which communication protocol is supported for localized digital data exchange?
A: The module supports Modbus RTU communication protocol for data acquisition and device interfacing.
Q: Does the module support fault-tolerant redundant wiring configurations?
A: Yes. The hardware is built specifically for redundant high-level analog input topologies to prevent single points of failure in process loops.
Field Installation Guidelines
- Shield Grounding Procedure: Connect all analog instrument cable shields to the dedicated cabinet ground bar at a single point to eliminate ground loops and minimize common-mode electrical noise.
- Cabinet Thermal Management: Maintain adequate vertical clearance around the 13.7 cm x 5.1 cm x 15.1 cm module housing within the marshalling rack to allow natural convection, keeping ambient conditions within the -40 to +85 deg C rating.
- Wiring and Power Distribution: Verify that the main DC power supply delivers a regulated voltage between 15 VDC and 30 VDC to the module input terminals before energizing field loops.
كيفية الحصول على عرض أسعار
تتبع الطلب
شركات الشحن
سياسة وشروط الاسترداد
شروط الضمان
منتجات ذات صله
- يؤدي اختيار تحديد إلى تحديث كامل للصفحة.