{"product_id":"p0916nz-i-a-series-discrete-input-fieldbus-module-foxboro","title":"P0916NZ I\/A Series Discrete Input Fieldbus Module | Foxboro","description":"\u003cp\u003eThe \u003cstrong\u003eP0916NZ\u003c\/strong\u003e is a 32-channel discrete input Fieldbus Module (FBM) for Foxboro I\/A Series DCS architectures. It acquires 24 VDC nominal digital field signals across an 18 to 30 VDC operating window, featuring channel-to-channel and channel-to-system galvanic isolation alongside live insertion and removal support on an energized FBM carrier backplane.\u003c\/p\u003e\n\u003ch3\u003eDiscrete Input Acquisition and Isolation\u003c\/h3\u003e\n\u003cp\u003eEach of the 32 isolated input circuits evaluates discrete contact states within an 18 to 30 VDC input range, filtering minor supply variations on 24 VDC field loops. Continuous polling and built-in fault diagnostics track input state stability and report channel health to the primary I\/A Series control processor.\u003c\/p\u003e\n\u003cp\u003eGalvanic isolation barriers separate individual input channels from one another and from the internal system logic bus. This electrical separation prevents ground loops and field-side voltage transients from coupling across adjacent channels or the rack backplane.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0916NZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input Fieldbus Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eFoxboro I\/A Series DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e32 isolated discrete input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC digital inputs (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-system isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e8 W nominal at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard FBM rack with carrier backplane (supports hot-swapping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlign the module rear connector with the designated slot on the FBM carrier backplane and press firmly until the mechanical locking latch engages.\u003c\/li\u003e\n\u003cli\u003eRoute incoming 24 VDC discrete field wiring to the associated terminal assembly with proper shield termination to limit electromagnetic interference on digital lines.\u003c\/li\u003e\n\u003cli\u003eMaintain enclosure ambient temperatures between 0 deg C and +60 deg C during continuous operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the Foxboro P0916NZ be replaced without shutting down neighboring channels?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports live insertion and removal (hot-swapping) on an energized FBM carrier backplane without disrupting active adjacent input channels.\u003c\/p\u003e\n\u003cp\u003eQ: What input voltage window does the P0916NZ accept for 24 VDC field signals?\u003c\/p\u003e\n\u003cp\u003eA: The discrete input circuitry accepts digital signals from 18 to 30 VDC around a 24 VDC nominal supply, filtering minor supply ripples before state evaluation.\u003c\/p\u003e\n\u003cp\u003eQ: How is the backplane protected from electrical faults on field wiring?\u003c\/p\u003e\n\u003cp\u003eA: Channel-to-channel and channel-to-system galvanic isolation barriers separate each discrete input circuit from the internal system bus to block ground loops and field transients.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":68269662339368,"sku":"P0916NZ","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FBM242P0916TA2_acfce299-453c-4daf-9087-7bb79b586d7d.jpg?v=1795418631","url":"https:\/\/www.powerdcs.com\/ar\/products\/p0916nz-i-a-series-discrete-input-fieldbus-module-foxboro","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}