{"product_id":"p0917xv-fbm215-218-foxboro-invensys-termination-assembly","title":"P0917XV | FBM215\/218 Foxboro Invensys Termination Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eP0917XV\u003c\/strong\u003e is a Foxboro Invensys termination assembly configured for I\/A Series control networks, supporting 8 isolated output channels for 4-20 mA DC loops with superimposed HART digital signals. It provides 600 V AC per-channel isolation, up to 750 Ohm load driving at 20 mA, and operation from -20 deg C to +60 deg C.\u003c\/p\u003e\n\u003ch3\u003eSignal Termination and Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eP0917XV\u003c\/strong\u003e interfaces field actuators and controller backplane connections across 8 isolated output channels using a 3-tier compression terminal layout. Per-channel isolation rated at 600 V AC helps prevent ground loops and electrical noise coupling between individual field circuits.\u003c\/p\u003e\n\u003cp\u003eEach loop supports 4-20 mA DC analog control alongside superimposed HART digital signaling up to a 750 Ohm maximum load at 20 mA. Keep loop resistance and field device burden within this 750 Ohm limit so analog current levels and HART digital communications remain within specification.\u003c\/p\u003e\n\u003ch3\u003eSystem Pairing and Environmental Ratings\u003c\/h3\u003e\n\u003cp\u003eDesigned for I\/A Series configurations associated with FBM215 and FBM218 modules, the \u003cstrong\u003eP0917XV\u003c\/strong\u003e is loop-powered (passive) and operates from -20 deg C to +60 deg C. It meets ISA Standard S71.04 Class G3 requirements and measures 14.5 cm x 13.5 cm x 6.5 cm with a weight of 0.8 kg.\u003c\/p\u003e\n\u003cp\u003eVerify module compatibility, DIN rail mounting space, and any required adapter hardware before installation. Where redundant FBM218 pairings or field device configuration tools are used, confirm exact system rules in your I\/A Series project engineering documentation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0917XV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro Invensys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTermination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eI\/A Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e8 isolated output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Compatibility\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC control loops with superimposed HART digital communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Load\u003c\/td\u003e\n\u003ctd\u003e750 Ohm at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e600 V AC per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Design\u003c\/td\u003e\n\u003ctd\u003e3-tier compression terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003ePassive (loop powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosive Environment Rating\u003c\/td\u003e\n\u003ctd\u003eISA Standard S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14.5 cm x 13.5 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eManufacturer Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the \u003cstrong\u003eP0917XV\u003c\/strong\u003e onto a DIN rail inside the I\/O cabinet with adequate clearance for wiring and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eConnect field conductors to the 3-tier compression terminals and verify tight mechanical clamping on each wire.\u003c\/li\u003e\n\u003cli\u003eTerminate cable drain wires to the designated grounding bus bar while maintaining the 600 V AC per-channel isolation design.\u003c\/li\u003e\n\u003cli\u003eConfirm compatibility with the target FBM module (such as FBM215 or FBM218) before seating the module into the assembly connector.\u003c\/li\u003e\n\u003cli\u003ePerform loop and HART communication verification before putting the output channel into active service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Can an FBM module be replaced on the Foxboro P0917XV without disconnecting field wiring?\u003c\/p\u003e\n\u003cp\u003eA: The terminal assembly physical layout allows FBM module removal and replacement without disturbing field wiring, subject to system maintenance state and safety procedures. Confirm hot-swap and power-down rules for your specific FBM module and I\/A Series revision before servicing.\u003c\/p\u003e\n\u003cp\u003eQ: What are the wiring and load limits on the P0917XV output channels?\u003c\/p\u003e\n\u003cp\u003eA: Each of the 8 isolated output channels supports up to 750 Ohm load at 20 mA for 4-20 mA and HART loop signaling. Verify loop impedance, cable capacitance, and distance limits against your specific I\/O module specifications and field wiring layout.\u003c\/p\u003e\n\u003cp\u003eQ: What is required when using redundant FBM218 modules with the P0917XV?\u003c\/p\u003e\n\u003cp\u003eA: Source notes indicate that redundant FBM218 setups may require an adapter (such as RH916QD) to bridge dual-module signals to the 8-channel termination interface. Check your I\/A Series hardware documentation to confirm exact adapter and redundancy requirements.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":68233921167656,"sku":"FBM215\/218 P0917XV","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FBM215218P0917XV.png?v=1795059623","url":"https:\/\/www.powerdcs.com\/ar\/products\/p0917xv-fbm215-218-foxboro-invensys-termination-assembly","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}