{"product_id":"tc-oav061-rev-k01-analog-output-module-honeywell","title":"TC-OAV061 REV K01 Analog Output Module | Honeywell","description":"\u003cp\u003eConfigured for high-precision analog signal generation in Experion PKS C200\/C300 rack systems, the \u003cstrong\u003eHoneywell TC-OAV061 REV K01\u003c\/strong\u003e (\u003cstrong\u003eTC-OAV061\u003c\/strong\u003e Analog Output Modules) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-OAV061 REV K01 (Catalog Base: TK-OAV061)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.5 cm x 14.0 cm x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C housing thermal envelope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 mA at 24 VDC external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e6 isolated analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Current\u003c\/td\u003e\n\u003ctd\u003e20 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Performance\u003c\/td\u003e\n\u003ctd\u003e12 bits resolution, 2 ms update time, +\/-0.1% FS accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe TC-OAV061 REV K01 converts internal digital control values into 6 galvanically isolated analog outputs across a 0 to 10 VDC range. Channel-to-channel isolation circuits prevent potential ground loop coupling and suppress transient field electrical interference from migrating into the backplane logic. The module maintains steady 12-bit D\/A conversion accuracy (+\/-0.1% FS) with a 2 ms update cycle, providing stable analog driving signals for field control devices while mitigating common-mode potential shifts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does replacing a TC-OAV061 REV K01 module require shutting down the main chassis rack power?\u003c\/p\u003e\n\u003cp\u003eA: Module removal under power (hot-swapping) is permitted on compatible backplanes provided local cabinet hazardous area conditions and site safety practices allow it.\u003c\/p\u003e\n\u003cp\u003eQ: How does channel-to-channel isolation on the TC-OAV061 REV K01 affect signal loop integrity?\u003c\/p\u003e\n\u003cp\u003eA: Galvanic separation prevents field ground loops between individual output loops, protecting adjacent channels if a ground fault occurs on a single field line.\u003c\/p\u003e\n\u003cp\u003eQ: What external supply is required to power the output circuitry on the TC-OAV061 REV K01?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on a nominal 24 VDC power supply drawer, consuming 100 mA under full operational load.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSlide the TC-OAV061 REV K01 module into the target rack chassis slot until the mechanical retention levers click securely into place.\u003c\/li\u003e\n\u003cli\u003eRoute 0 to 10 VDC signal conductors using twisted, shielded cable pairs to minimize external electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnect signal cable shield drain wires to the central enclosure grounding bus at a single landing point.\u003c\/li\u003e\n\u003cli\u003eVerify correct terminal screw torque and wiring polarity before applying 24 VDC auxiliary loop power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52364651823400,"sku":"TC-OAV061","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/TK-OAV061_Cocoai.png?v=1789025754","url":"https:\/\/www.powerdcs.com\/ar\/products\/tc-oav061-rev-k01-analog-output-module-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}