Triconex EM 2291 Internal System Interface Module
Specifications
Manufacturer: Triconex
Product No.: EM 2291
Condition: 10 العناصر الموجودة في المخزون
Product Type: System Interface Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 1000g
Shipping port: Xiamen
Warranty: 12 months
تفاصيل المنتج
وصف
The Triconex EM 2291 is an internal system interface module designed for Triconex Safety Instrumented Systems (SIS). Installed in a system chassis, it operates from a 24 VDC nominal power supply and supports fault-tolerant safety architectures across a -20 deg C to +60 deg C operating range.
System Role and Configuration
Within a Triconex safety control architecture, the Triconex EM 2291 provides an internal system interface function and is designated in the provided documentation as an I/O module. Chassis-based mounting keeps the module mechanically seated within the rack assembly for cabinet and panel integration.
The module operates from a nominal 24 VDC supply and is rated for non-condensing humidity from 5% to 95%. Where redundant or fault-tolerant configurations are deployed at the system level, hardware and chassis layout must follow the specific Triconex system design.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | EM 2291 |
| Brand | Triconex |
| Product Type | Internal System Interface Module / I/O Module |
| Power Supply | 24 VDC nominal |
| Dimensions | 10.2" x 6.3" x 3.1" |
| Weight | 2.2 lbs |
| Mounting | Chassis-based installation |
| Operating Temperature | -20 deg C to +60 deg C |
| Storage Temperature | -40 deg C to +85 deg C |
| Humidity Range | 5% to 95%, non-condensing |
Installation and Environmental Limits
Mount the module securely inside a compatible Triconex chassis in an environment maintained between -20 deg C and +60 deg C during operation. When stored prior to installation, keep conditions within -40 deg C to +85 deg C and avoid moisture condensation across the 5% to 95% humidity range.
Frequently Asked Questions
Q: What power supply does the Triconex EM 2291 require?
A: It operates from a 24 VDC nominal power supply. Verify that the system power distribution matches the 24 VDC nominal rating before energizing the chassis.
Q: How is the Triconex EM 2291 mounted?
A: It uses chassis-based installation rather than standalone surface mounting. Confirm that the target chassis provides an open slot and matches the 10.2" x 6.3" x 3.1" envelope.
Q: What temperature and humidity limits apply to this module?
A: The rated operating temperature is -20 deg C to +60 deg C, and the storage temperature range is -40 deg C to +85 deg C. Relative humidity must stay between 5% and 95%, non-condensing.