{"product_id":"8u-paina1-honeywell-analog-input-module","title":"8U-PAINA1 Honeywell Analog Input Module","description":"\u003cp\u003eConfigured for multi-channel analog signal acquisition in Honeywell Experion PKS C300 platforms, the \u003cstrong\u003eHoneywell 8U-PAINA1\u003c\/strong\u003e (\u003cstrong\u003e8U-PAINA1\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8U-PAINA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.34 kg (340 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard IOTA module housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 single-ended channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (Non-HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 ohms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003e500 VAC RMS channel-to-ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003eLess than 100 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA Loop Processing and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8U-PAINA1\u003c\/strong\u003e incorporates high-precision analog-to-digital processing stages operating across a standard single-ended 4-20 mA signal range without HART communication overhead. Integrated per-channel galvanic isolation rated at 500 VAC RMS shields central backplane logic from ground potential offsets and common-mode voltage spikes. Onboard signal conditioning circuitry with a 250 ohm input impedance stabilizes input data acquisition, providing precise high-level signal filtering across a rapid update rate of less than 100 ms per channel.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 8U-PAINA1 analog input module support digital HART protocol pass-through?\u003c\/p\u003e\n\u003cp\u003eA: No, the 8U-PAINA1 is designed specifically for standard non-HART single-ended 4-20 mA analog input signals.\u003c\/p\u003e\n\u003cp\u003eQ: How is the 8U-PAINA1 module physically mounted into the Experion I\/O architecture?\u003c\/p\u003e\n\u003cp\u003eA: The module features a snap-in form factor designed for direct installation onto compatible Input Output Termination Assembly (IOTA) carriers.\u003c\/p\u003e\n\u003cp\u003eQ: What level of electrical isolation is provided between field channels and ground?\u003c\/p\u003e\n\u003cp\u003eA: The module provides per-channel galvanic isolation rated to withstand 500 VAC RMS channel-to-ground electrical potential.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the Experion IOTA mounting rail is connected to main cabinet Earth ground using a low-impedance conductor (minimum 4 mm2 \/ 10 AWG).\u003c\/li\u003e\n\u003cli\u003eDe-energize 24 VDC loop power supplies before inserting or snapping the 8U-PAINA1 module onto its designated IOTA baseplate position.\u003c\/li\u003e\n\u003cli\u003eRoute 4-20 mA analog input wiring using shielded twisted-pair cables, maintaining a minimum 300 mm separation from high-voltage AC conductors and drive leads.\u003c\/li\u003e\n\u003cli\u003eTerminate overall signal cable shields at a single point on the enclosure Earth ground bar to eliminate circulating ground loop currents.\u003c\/li\u003e\n\u003cli\u003eVerify proper seating of the module locking mechanisms to maintain vibration-resistant connectivity to the IOTA backplane interface.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52318150164776,"sku":"8U-PAINA1","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/8C-PAIH5151454352-1751_55b7cc4f-c211-4b65-b1c9-01095a6f8094.png?v=1788316530","url":"https:\/\/www.powerdcs.com\/es\/products\/8u-paina1-honeywell-analog-input-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}