{"product_id":"900cr10-00-honeywell-900-control-station-operator-interface-module","title":"900CR10-00 Honeywell 900 Control Station Operator Interface Module","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eConfigured for process visualization, control execution, and diagnostics in Honeywell ControlEdge HC900 platforms, the \u003cstrong\u003eHoneywell 900CR10-00\u003c\/strong\u003e (\u003cstrong\u003e900CR10\u003c\/strong\u003e Operator Interface Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900CR10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.4 in display panel mount footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 to 30 VDC input range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOperator Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e10.4 in TFT LCD (640 x 480 pixels VGA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive touch panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Unit\u003c\/td\u003e\n\u003ctd\u003eARM-based industrial CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Storage\u003c\/td\u003e\n\u003ctd\u003eInternal flash memory; CompactFlash slot (up to 2 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 x RS-232, 1 x RS-422\/485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork \u0026amp; USB\u003c\/td\u003e\n\u003ctd\u003e1 x Ethernet (10\/100Base-TX), 2 x USB (host\/device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBezel Protection\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X \/ IP66 front panel rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell ControlEdge HC900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 900CR10-00 operator terminal interfaces directly with Honeywell HC900 controller racks to display real-time field data derived from 4-20 mA HART loop protocol transmitters and discrete I\/O subsystems. Utilizing dedicated Ethernet and serial communications, the unit streams alarm summaries, historical data logging, and process recipes without introducing latency to primary loop execution. High-density isolation on physical interfaces protects the ARM-based processing core from common-mode electrical transients across distributed control system networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What programming tool is required to configure screens and trend logs on the terminal?\u003c\/p\u003e\n\u003cp\u003eA: Screen configurations, recipe profiles, and data logging setups must be deployed using Honeywell Station Designer software version 3.1.7100 or later.\u003c\/p\u003e\n\u003cp\u003eQ: What external storage media are supported for process data archiving?\u003c\/p\u003e\n\u003cp\u003eA: Historical trends and alarm event logs can be recorded directly to an onboard CompactFlash card (up to 2 GB) or via external USB memory devices.\u003c\/p\u003e\n\u003cp\u003eQ: Can the unit communicate simultaneously over serial and Ethernet connections?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the panel incorporates independent interface controllers allowing simultaneous operation over 10\/100Base-TX Ethernet, dual RS-232 ports, and an RS-422\/485 serial port.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCut panel enclosure opening to match manufacturer cutout dimensions and ensure structural integrity before mounting.\u003c\/li\u003e\n\u003cli\u003eVerify that the front bezel sealing gasket is aligned flush against the panel surface to maintain NEMA 4X \/ IP66 ingress protection.\u003c\/li\u003e\n\u003cli\u003eConnect dedicated chassis ground conductors directly to the unit ground terminal using low-impedance copper wire.\u003c\/li\u003e\n\u003cli\u003eRoute 10 to 30 VDC power conductors away from high-voltage motor or drive cabling to avoid electromagnetic interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67865215893800,"sku":"900CR10-00","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/900CR10-00.png?v=1791622081","url":"https:\/\/www.powerdcs.com\/es\/products\/900cr10-00-honeywell-900-control-station-operator-interface-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}