{"product_id":"900rta-l001-remote-terminal-assembly-module-honeywell","title":"900RTA-L001 Remote Terminal Assembly Module | Honeywell","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900RTA-L001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e900RTA\u003c\/strong\u003e Remote Terminal Panel Module, operates as a dedicated hardware component for field signal termination and analog input isolation within Honeywell HC900 control system racks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900RTA-L001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRemote Terminal Assembly (RTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003ePLC Module \/ Terminal Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channel Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input (4-20 mA \/ Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lbs (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail \/ Rack Terminal Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe termination assembly incorporates channel-to-channel isolation and integrated signal conditioning circuits designed to maintain signal integrity during high-density 4-20 mA HART loop protocol routing. Internal cold junction compensation (CJC) sensors provide accurate temperature reference calculations across thermocouple input terminals, preventing thermal gradient errors across adjacent wiring blocks. Shielded wiring terminations suppress high-frequency electrical noise and common-mode transients before field signals reach the primary I\/O processing backplane.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the RTA board mitigate thermocouple thermal measurement drift?\u003c\/p\u003e\n\u003cp\u003eA: Cold junction compensation (CJC) thermistors mounted directly on the terminal block sense local ambient changes, allowing the controller to dynamically correct thermocouple millivolt offsets.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current loop drive capacity for the analog input channels on this module?\u003c\/p\u003e\n\u003cp\u003eA: The module is rated for an internal current load of 80 mA across its power distribution circuit for field loop transmitters.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 900RTA-L001 terminal assembly be hot-swapped while field wiring is powered?\u003c\/p\u003e\n\u003cp\u003eA: Field wiring blocks can be disconnected using the removable terminal block assembly, but complete module swapping requires isolating field circuit power to prevent transient arcs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all external 24 VDC power supplies connected to field transmitters before wiring the terminal block.\u003c\/li\u003e\n\u003cli\u003eStrip field conductor insulation to exactly 6 mm to ensure complete copper contact without exposing bare wire outside the terminal cage.\u003c\/li\u003e\n\u003cli\u003eConnect signal cable shields to the dedicated chassis ground bar using a low-impedance ground strap; do not ground shields at both ends to avoid ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify screw terminal torque settings do not exceed 0.5 Nm (4.4 in-lbs) to avoid damaging terminal block housing threads.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum clearance of 50 mm between analog input field cables and high-voltage AC power lines within cabinet wire ducts.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67850759176488,"sku":"900RTA-L001","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/900RTA-L001_Cocoai.png?v=1791445153","url":"https:\/\/www.powerdcs.com\/es\/products\/900rta-l001-remote-terminal-assembly-module-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}